Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2014.tde-16112015-154649
Documento
Autor
Nombre completo
Paulo Henrique Brossi Sabia
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Lima, Raul Gonzalez (Presidente)
Moura, Fernando Silva de
Silva, Erasmo Simao da
Título en portugués
Projeto e construção de um equipamento biaxial para a caracterização mecânica de tecidos biológicos tubulares.
Palabras clave en portugués
Aneurisma de aorta abdominal
Aorta abdominal
Caracterização mecânica
Máquina de ensaios
Tecidos biológicos
Teste biaxial
Resumen en portugués
Com a evolução da medicina e o consequente envelhecimento da população, o aneurisma de aorta abdominal (AAA) se tornou uma doença cada vez mais presente, sobretudo em homens. A falta de conhecimento detalhado do comportamento mecânico do tecido aórtico abdominal é o principal gargalo no refinamento do critério para a recomendação de cirurgia corretiva, resultando, ainda hoje, no óbito decorrente da ruptura desses aneurismas. O entendimento do comportamento mecânico desse tecido permitirá o refinamento do critério atual, salvando mais vidas. Esse entendimento pode ser obtido através da Mecânica do Contínuo, utilizando dados experimentais de ensaios mecânicos para avaliar e descrever o comportamento do material. Para que isso ocorra, é necessário que o teste seja feito em dois eixos independentes. No presente trabalho, foram escolhidos os eixos longitudinal e circunferencial para a realização de testes mecânicos, levando em consideração aspectos de metodologias já utilizadas, seus pontos fortes e deficiências. São apresentados o projeto, a construção e e a calibração de um equipamento para ensaios biaxiais de tecidos biológicos tubulares, extraídos de cadáveres, e testados até a ruptura, com a possibilidade de realização de ensaios de pré-condicionamento. Tubos de látex foram utilizados na calibração do equipamento, de cuja utilização é esperada grande contribuição na ampliação do conhecimento da probabilidade de ruptura de AAAs e em uma melhor compreensão do comportamento do tecido da uretra peniana.
Título en inglés
Project and manufacturing of a biaxial equipment for the mechanical characterization of tubulst-shaped biological tissues.
Palabras clave en inglés
Abdominal aorta
Abdominal aortic aneurysm
Biaxial test
Biological tissues
Mechanical characterization
Testing machine
Resumen en inglés
The evolution of Medicine has enabled humans to live longer. With that, the incidence of abdominal aortic aneurysms (AAAs) has grown, especially among males. The lack of detailed knowledge on the mechanical behavior of the abdominal aortic tissue is the main bottleneck in the improvement of the criterion for recommending corrective surgery. Therefore, many patients still die from the rupture of those aneurysms. Better understanding of the tissues mechanical behavior will allow the refinement of todays criterion, thus saving more lives. This understanding can be obtained from Continuum Mechanics, using mechanical test experimental data to evaluate and describe the behavior of the material. The data has to come from tests performed in two independet axes. This Masters thesis presents the project, manufacturing and calibration of an apparatus for the test of cylindrical biological tissues in two directions, longitudinal and circumferential. Aspects of pre-existent tests and methods and their positive and negative sides were taken into account. The specimens will come from cadavers, and it will be possible to pre-condition them, as well as to test them to the rupture. Latex tubes were used in the calibration of the apparatus, whose utilization is expected to improve the knowledge on AAA rupture probability, as well as to improve the comprehension of the penile urethral tissues behavior.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-11-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.