Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2014.tde-16112015-154649
Document
Author
Full name
Paulo Henrique Brossi Sabia
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2014
Supervisor
Committee
Lima, Raul Gonzalez (President)
Moura, Fernando Silva de
Silva, Erasmo Simao da
Title in Portuguese
Projeto e construção de um equipamento biaxial para a caracterização mecânica de tecidos biológicos tubulares.
Keywords in Portuguese
Aneurisma de aorta abdominal
Aorta abdominal
Caracterização mecânica
Máquina de ensaios
Tecidos biológicos
Teste biaxial
Abstract in Portuguese
Com a evolução da medicina e o consequente envelhecimento da população, o aneurisma de aorta abdominal (AAA) se tornou uma doença cada vez mais presente, sobretudo em homens. A falta de conhecimento detalhado do comportamento mecânico do tecido aórtico abdominal é o principal gargalo no refinamento do critério para a recomendação de cirurgia corretiva, resultando, ainda hoje, no óbito decorrente da ruptura desses aneurismas. O entendimento do comportamento mecânico desse tecido permitirá o refinamento do critério atual, salvando mais vidas. Esse entendimento pode ser obtido através da Mecânica do Contínuo, utilizando dados experimentais de ensaios mecânicos para avaliar e descrever o comportamento do material. Para que isso ocorra, é necessário que o teste seja feito em dois eixos independentes. No presente trabalho, foram escolhidos os eixos longitudinal e circunferencial para a realização de testes mecânicos, levando em consideração aspectos de metodologias já utilizadas, seus pontos fortes e deficiências. São apresentados o projeto, a construção e e a calibração de um equipamento para ensaios biaxiais de tecidos biológicos tubulares, extraídos de cadáveres, e testados até a ruptura, com a possibilidade de realização de ensaios de pré-condicionamento. Tubos de látex foram utilizados na calibração do equipamento, de cuja utilização é esperada grande contribuição na ampliação do conhecimento da probabilidade de ruptura de AAAs e em uma melhor compreensão do comportamento do tecido da uretra peniana.
Title in English
Project and manufacturing of a biaxial equipment for the mechanical characterization of tubulst-shaped biological tissues.
Keywords in English
Abdominal aorta
Abdominal aortic aneurysm
Biaxial test
Biological tissues
Mechanical characterization
Testing machine
Abstract in English
The evolution of Medicine has enabled humans to live longer. With that, the incidence of abdominal aortic aneurysms (AAAs) has grown, especially among males. The lack of detailed knowledge on the mechanical behavior of the abdominal aortic tissue is the main bottleneck in the improvement of the criterion for recommending corrective surgery. Therefore, many patients still die from the rupture of those aneurysms. Better understanding of the tissues mechanical behavior will allow the refinement of todays criterion, thus saving more lives. This understanding can be obtained from Continuum Mechanics, using mechanical test experimental data to evaluate and describe the behavior of the material. The data has to come from tests performed in two independet axes. This Masters thesis presents the project, manufacturing and calibration of an apparatus for the test of cylindrical biological tissues in two directions, longitudinal and circumferential. Aspects of pre-existent tests and methods and their positive and negative sides were taken into account. The specimens will come from cadavers, and it will be possible to pre-condition them, as well as to test them to the rupture. Latex tubes were used in the calibration of the apparatus, whose utilization is expected to improve the knowledge on AAA rupture probability, as well as to improve the comprehension of the penile urethral tissues behavior.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-11-26
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.