• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2020.tde-20012021-122959
Documento
Autor
Nombre completo
Bernardo Luiz Harry Diniz Lemos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2020
Director
Tribunal
Meneghini, Julio Romano (Presidente)
Cestari, Idágene Aparecida
Freire, César Monzu
Título en portugués
Investigação do escoamento no dispositivo de assistência ventricular pediátrico do Incor por velocimetria de imagem de partículas resolvida no tempo.
Palabras clave en portugués
Dinâmica dos fluídos
Insuficiência cardíaca
Ventrículo cardíaco
Resumen en portugués
Todos os anos milhões de pessoas morrem devido às doenças cardiovasculares em todo o mundo. Uma delas é a insuficiência cardíaca, que consiste na incapacidade do coração em bombear o sangue para o corpo. Para uma parte dos acometidos por esta patologia, a solução consiste no transplante de coração. Entretanto, poucos órgãos estão disponíveis para transplante, o que produz uma lista de espera extensa e demorada. A fim de evitar a morte de pacientes durante a espera, os dispositivos de assistência ventricular (DAV) são implantados para suplementar a função do coração. Os DAVs não são biológicos e, portanto, precisam de constantes aprimoramentos para evitar danos ao sangue como, por exemplo, a formação de trombos e a hemólise. Os aprimoramentos são especialmente interessantes para o DAV pediátrico pois as crianças e adolescente que os utilizam estão em uma ampla faixa de idades, tamanhos e demandas corporais. Uma maneira de aperfeiçoar o DAVP está na investigação da fluidodinâmica do dispositivo. A aplicação da velocimetria de imagem de partículas (PIV), técnica óptica não invasiva, permite mensurar grandezas físicas do escoamento no interior do dispositivo, como campos de velocidade e tensões de cisalhamento instantâneos. Todavia, o PIV apresenta desvantagens causadas por fontes ruidosas, por exemplo: distorções, reflexões do laser e sombras causadas pela geometria complexa e pelo diafragma do DAVP pulsátil. Além de desenvolver uma metodologia para garantir a qualidade das medidas PIV, o objetivo deste trabalho é avaliar o funcionamento do DAVP do Instituto do Coração (InCor) em 70 batidas por minuto com dois ângulos de válvula de entrada, 0º e 30º, para avaliar a fluidodinâmica do DAVP e consequentemente a formação de trombos e a hemólise com o PIV resolvida no tempo. Os resultados apontaram para maior penetração do jato diastólico e lavagem do dispositivo quando a válvula de entrada esteve a 0º e menor regurgitação para a válvula a 30º.
Título en inglés
Investigation of the flow in the InCor Pediatric Ventricular Assist Device by time resolved particle image velocimetry.
Palabras clave en inglés
Fluid dynamics
Particle image velocimetry
Ventricular assist device
Resumen en inglés
Every year millions of people die from cardiovascular disease worldwide. One of these diseases is heart failure (HF), which is the inability of the heart to pump blood to the body. For a part of those affected by this pathology, the solution consists of heart transplantation. However, few organs are available for transplantation, which produces an extensive and lengthy waiting list. In order to prevent patient death while waiting, ventricular assist devices (VADs) are implanted to supplement heart function. VADs are not biological and therefore need constant improvement to prevent damage to the blood such as thrombus formation and hemolysis. The enhancements are especially interesting for pediatric VAD (PVAD) because the children and adolescents who use them are in a wide range of ages, sizes and body demands. One way to improve PVAD is by investigating the device's fluid dynamics. The application of particle image velocimetry (PIV), a non-invasive optical technique, allows the measurement of physical quantities of the flow within the device, such as instantaneous velocity fields and shear stresses. However, PIV has disadvantages caused by noisy sources, for example: distortions, laser reflections, and shadows caused by the complex geometry of pulsed DAVP diaphragm. In addition to developing a methodology to guarantee the quality of PIV measures, the objective of this work is to evaluate the functioning of the DAVP from Instituto do Coração (InCor) at 70 beats per minute with two inlet valve angles, 0º and 30º, to evaluate the fluid dynamics of PVAD and consequently thrombus formation and hemolysis with time-resolved PIV. The results shown better penetration of the diastolic jet and device washing when the inlet valve was at 0º and less regurgitation for the valve at 30º.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2021-01-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.