Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.3.2008.tde-09022009-135131
Documento
Autor
Nome completo
Christian Daniel Tacuse Begazo
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2008
Orientador
Banca examinadora
Simões-Moreira, José Roberto (Presidente)
Matai, Patrícia Helena Lara dos Santos
Torres, Ednildo Andrade
Título em português
Avaliação de um ciclo de liquefação usando a tecnologia de refrigerante misto para plantas de pequena escala de GNL.
Palavras-chave em português
Estado líquido
Gás natural
Refrigeração
Termodinâmica
Resumo em português
Este trabalho tem como objetivo analisar a tecnologia do ciclo refrigerante misto para obtenção de gás natural liquefeito (GNL). Nessa tecnologia, o GNL é obtido por meio do seu resfriamento através de um ciclo de refrigeração, cujo fluido refrigerante é formado por uma mistura de diversos componentes. O ciclo de refrigeração é usado para resfriar a corrente de gás natural até as condições criogênicas por meio de um trocador de calor. A determinação da composição ótima dessa mistura de refrigerantes é de suma importância para a correta e eficiente operação da planta. O modelo termodinâmico para o cálculo de equilíbrio de fases dos componentes da mistura refrigerante é o baseado na Lei de Raoult, válido para misturas e soluções ideais. Inicialmente, revisam-se os conceitos de refrigerantes mistos, curvas compostas e o ponto de pinça (pinch point), utilizados na implementação da solução computacional. A aplicação dos modelos de gás e solução ideal influencia nos resultados, mas, não obstante, produz bons resultados como os obtidos no presente trabalho. A operação eficiente do ciclo depende, sobretudo, de três parâmetros principais, quais sejam: vazão da mistura refrigerante, razão de pressões alta e baixa do ciclo de refrigeração e composição da mistura refrigerante. Da análise dos resultados obtidos conclui-se que a alteração nas proporções da composição do refrigerante muda significativamente a forma das curvas composta quente e composta fria, quando comparados à alteração dos níveis de pressão e da vazão do ciclo refrigerante. Entretanto, a operacionalização do ciclo somente ocorre se um dado conjunto de valores daqueles parâmetros satisfaça uma determinada diferença mínima de temperatura, ou ponto de pinça, entre as curvas composta quente e composta fria dentro do trocador de calor. Assim, a operação eficiente do ciclo de refrigeração requer a otimização daqueles três parâmetros operacionais.
Título em inglês
Analysis of a liquefaction cycle using mixed refrigerant technology for LNG small scale plants.
Palavras-chave em inglês
Liquefaction
Liquefied natural gas
Mixed refrigerant
Pinch analysis
Small scale plants
Resumo em inglês
This work has the objective of analyzing the technology of mixed refrigerant cycle for obtaining liquefied natural gas (LNG). In that technology, the liquefied natural gas is obtained by means of cooling through a refrigeration cycle, whose fluid refrigerant is formed by a mixture of various components. The refrigeration cycle is used to cool the natural gas stream to cryogenic condition with the use of a heat exchanger. The determination of the optimal composition of this refrigerant mixture is very important for the correct and efficient operation of the plant. The thermodynamic model for the equilibrium phase calculation of the refrigerant mixture is based on the Law of Raoult, which is valid for ideal mixtures and solutions. Initially, the concepts of refrigerant mixture, composite curves and pinch point used in the implementation of the numerical solution were reviewed. The application of ideal-gas and ideal-solution models has influence on the results. Nevertheless, it produces good results as those obtained in the present work. The efficient operation of the cycle depends essentially of three key parameters, which are: refrigerant flow rate, the ratio of high to low pressures of the refrigerant cycle and the mixed refrigerant composition. The results indicated that the composition variation of the refrigerant changes significantly the shape of hot and cold composite curves in comparison to the modification in the pressure levels and the refrigerant flow rate of the refrigerant cycle. However, the process will operate only if a given set of values of those parameters satisfies a minimum temperature difference, or pinch point, between the hot and cold composite curves within the heat exchanger. Thus, the efficient operation of the refrigerant cycle requires the optimization of those three operational parameters.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2009-02-20
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.