• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2002.tde-16042024-143134
Document
Auteur
Nom complet
Denis Luque Martins
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2002
Directeur
Jury
Souza, Gilberto Francisco Martha de (Président)
Machado, Izabel Fernanda
Ruggieri, Claudio
Titre en portugais
Confiabilidade na estruturação de carroceria de veículos.
Mots-clés en portugais
Carroçaria (Confiabilidade)
Veículos
Resumé en portugais
Neste trabalho estuda-se a confiabilidade na estruturação de carrocerias de veículos, tomando como base de estudo a estruturação primária (framing I) do veículo de passeio Astra modelo HB (hatch back), produzido na fábrica de São Caetano do Sul da General Motors do Brasil. A estruturação primária consiste na união do compartimento do motor (front end) com o assoalho conjunto completo. A coleta de dados da carroceria é feita através de um sistema de medição a laser. O sistema instalado mede a variação do posicionamento de 35 pontos do veículo com relação à cota nominal nas direções X, Y e Z. Mostra-se aqui uma avaliação dos tipos de relatórios emitidos por este sistema e propõem-se melhorias a fim de direcionar as especificações técnicas para futuras compras de sistemas semelhantes.
Titre en anglais
Untitled in english
Mots-clés en anglais
Bodywork (Reliability)
Vehicles
Resumé en anglais
This is a study of the reliability on vehicles "Body in White" build up systems, taking the vehicle Astra hatch back model as the basic case on its primary framing build up, produced at General Motors do Brasil, São Caetano do Sul plant. The primary framing consists in joining the front end assembly to the underbody assembly. Data is collected by a laser measurement system. The installed equipment determines the variation of 35 points from nominal quote in X, Y and Z directions. It is shown here an analysis of types of reports printed by this system and improvements are proposed to guide technical specifications in future acquisitions of similar systems.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
DENISLUQUEMARTINS.pdf (3.49 Mbytes)
Date de Publication
2024-04-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.