• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2014.tde-29122014-172152
Documento
Autor
Nombre completo
Jean Felix Cabette
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Marinho, Fernando Antônio Medeiros (Presidente)
Orlando, Celso
Tsuha, Cristina de Hollanda Cavalcanti
Título en portugués
Análise dos métodos semi-empíricos utilizados para a estimativa da capacidade de carga de estacas pré-fabricadas com base em resultados de ensaios de carregamento dinâmico.
Palabras clave en portugués
Capacidade de carga lateral
Carregamento nas estruturas
Estacas
Processos pré-fabricados
Resumen en portugués
A fundação profunda tem como objetivo realizar a transferência das cargas provenientes da superestrutura ao solo, ou seja, deve-se considerar sempre a interação fundação-solo, para estimativa da capacidade de carga de suporte da estrutura. Segundo Avelino (2006) com o surgimento dos ensaios de carregamento dinâmico, o controle do estaqueamento de fundações profundas desenvolveu-se significativamente nos últimos vinte anos devido à facilidade na execução desses ensaios e seu relativo baixo custo. No Brasil, há um predomínio praticamente absoluto dos métodos CASE e CAPWAP. O trabalho tem por objetivo analisar o método semi-empírico que preveja com maior confiabilidade a capacidade de carga de estacas pré-fabricadas cravadas em região de solo mole. Para atingir este objetivo serão analisadas estacas de concreto protendido com seção transversal quadrada 230mmx230mm, utilizadas como fundação de habitações populares em uma obra promovida pela Companhia de Desenvolvimento Habitacional e Urbano do Estado de São Paulo (CDHU), na cidade de Cubatão, São Paulo. Neste trabalho serão apresentados os resultados de capacidade de carga das estacas determinados através da aplicação de alguns métodos consagrados, como o Decourt-Quaresma (1978) e Aoki-Velloso (1975), que utilizam resultados de sondagens a percussão de simples reconhecimento. Estes valores de capacidade de carga serão comparados aos obtidos através de uma série de ensaios de carregamento dinâmico tendo como foco a capacidade de carga da estaca, através das analises CAPWAP. Estes ensaios são localizados próximos aos respectivos furos de sondagens cujos resultados foram utilizados para previsão da capacidade de carga.
Título en inglés
Analysis of semi-empirical methods used to estimate the load capacity of prefabricated piles based on results of dynamic load testing.
Palabras clave en inglés
Loading on structures
Pre-manufactured processes
Side capacity
Stakes
Resumen en inglés
A deep foundation is a structural element that aims to conduct the transfer of loads from the superstructure to the ground, ie, one should always consider the foundation-soil interaction to predict the load capacity of the frame support. According to Avelino (2006) with the emergence of dynamic loading tests, the control staking of deep foundations has developed significantly over the last twenty years due to the ease in performing those tests and their relative low cost. In Brazil, there is an almost absolute predominance of CASE and CAPWAP methods. The work aims to compare the values of load capacity predicted by semi-empirical methods of prefabricated concrete piles driven in to the soft soil with the values obtained through dynamic load tests. For this, pre-stressed concrete piles were analyzed with square cross section 230mmx230mm, used as popular housing foundation in a project promoted by the Company of Housing and Urban Development of the State of São Paulo (CDHU) in the city of Cubatão, São Paulo. The semi-empiric methods used follow the Decourt and Quaresma (1978), Aoki and Velloso (1975), methods, using results of standard penetration test (SPT). These load capacity values will be compared to those obtained through a series of dynamic loading test focusing on the load capacity obtained through the CAPWAP analysis.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-01-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.