• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.3.2012.tde-16072013-122419
Document
Auteur
Nom complet
Denis Kenhiti Suzuki
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2012
Directeur
Jury
Boscov, Maria Eugênia Gimenez (Président)
Esquivel, Edmundo Rogério
Queiroz, Paulo Ivo Braga de
Titre en portugais
Verticalização de aterros sanitários por meio de reforço com geogrelhas e diques periféricos alteados pelo método de montante.
Mots-clés en portugais
Aterros sanitários
Estabilidade estrutural
Geometria e modelagem computacional
Geossintéticos
Resíduos urbanos
Taludes
Resumé en portugais
Este trabalho apresenta resultados de análises de estabilidade por métodos de equilíbrio limite e análises tensão-deformação para um aterro sanitário de grande porte reforçado com geossintéticos e alteado com diques periféricos sucessivos segundo o método de montante de barragens de rejeitos, visando a aumentar sua capacidade de armazenamento. Os valores dos parâmetros de resistência elásticos e elasto-plásticos dos materiais foram definidos com base na bibliografia, privilegiando-se os obtidos em campo. Os parâmetros dos reforços geossintéticos (geogrelhas) foram obtidos dos catálogos técnicos de empresa fabricante de geogrelhas. Nas análises equilíbrio-limite verificou-se também a influência das pressões neutras nos fatores de segurança por meio da variação do parâmetro de pressão ru de 0 a 0,3. Os resultados dos métodos de equilíbrio limite mostraram que a construção de diques periféricos sucessivos não aumenta significativamente o fator de segurança do aterro para qualquer altura e a de diques reforçados aumenta-o para alturas até 30m. Por outro lado, o reforço dentro do maciço aumenta consideravelmente o fator de segurança para qualquer altura do aterro. As pressões neutras no maciço podem reduzir significativamente o fator de segurança, em até 25% para as configurações propostas. O fator de segurança 1,5 é atingido para ru = 0,2, para as alturas de até 30m nas configurações com reforço no interior do maciço sanitário. As análises tensão-deformação mostraram que as deformações são principalmente verticais, sendo que as horizontais representam até 30% das totais. As deformações verticais máximas foram de 4%, valor muito inferior aos encontrados na bibliografia em aterros monitorados (10 a 40%), provavelmente porque as contribuições da decomposição da matéria orgânica e do creep ao longo do tempo superam o efeito do peso próprio do maciço. A análise conjunta das duas metodologias mostra que os fatores de segurança obtidos nas análises tensão-deformação são muito próximos aos obtidos nas análises equilíbrio-limite para ru =0,1; que o uso de reforços no interior do maciço sanitário proporciona um aumento no fator de segurança da ordem de 30%, o que justifica a continuação deste estudo focalizando aspectos práticos construtivos e operacionais; e que a configuração em diques sucessivos e maciço sanitário reforçado mostrou-se, dentre as alternativas estudadas, a mais eficiente e eficaz para a configuração de aterro estudada, uma vez que permitiu obter o fator de segurança desejado sem a necessidade de reforço dos diques de solos.
Titre en anglais
Verticalization of waste landfill by means reinforcement with geogrids and peripheral soil dikes by the raising upstream method.
Mots-clés en anglais
Geometry and computational modeling
Municipal waste
Slopes
Structural stability
Waste landfills
Resumé en anglais
This paper presents results of stability analysis by limit-equilibrium methods and stress-strain analysis for a large sanitary landfill reinforced with geosynthetics and raising with perimeters soil dikes according to the method used in tailing dams in order to increase their ability to storage. The values of strength parameters, elastic and elasto-plastic materials were defined based on the literature, privileging those obtained in the field. The parameters of geosynthetic reinforcements (geogrids) were obtained from the catalogs of technical manufacturer of geogrid. The analyzes limit-equilibrium were verified also the influence of the factors of safety pore pressures by varying the parameter pressure ru 0 to 0.3. The results of limit-equilibrium methods showed that the construction of dikes successive peripheral does not significantly increase the safety factor of the landfill for any height and the use of reinforced dikes increases it to heights up to 30m. Moreover, the reinforcement into the mass increases substantially the safety factor for any height of the landfill. The pore pressures in mass can significantly reduce the safety factor in up to 25% for the proposed configurations. The safety factor of 1.5 is achieved for ru =0.2, for heights up to 30m with enhanced settings inside the massive sanitary. The stress-strain analyzes showed that the deformations are mainly vertical and the horizontal represent up to 30% of the total. The maximum vertical deformations were 4%, value that is much lower than those described in the bibliography for landfill sites monitored (10-40%), probably because the contributions of organic matter decomposition and "creep" over time outweigh the effect of self-weight of the massif. The joint analysis of the both methods show that safety factors obtained in the stress-strain analyzes are very near the limit-equilibrium analyses for ru =0.1, that the use of solid reinforcement inside the landfill provides a factor increase in security of the order of 30%, its which justifies the continuation of this study focusing on practical aspects of construction and operational and that the configuration in successive dikes and massive sanitary reinforced proved to be, among the alternatives studied, the most efficient and effective configuration of landfill studied, since it allowed to obtain the desired safety factor without the need to strengthen the soil dikes.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2013-07-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.