• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2014.tde-29122014-175150
Documento
Autor
Nombre completo
Everton Shigueaki Yoshida
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2014
Director
Tribunal
Manassero Junior, Giovanni (Presidente)
Pereira, Carlos Eduardo de Morais
Sousa, Thales
Título en portugués
Algoritmos para análise automática de faltas em sistemas elétricos de potência.
Palabras clave en portugués
Algoritmos genéticos
Análise automática de faltas
Rede de distribuição
Transformada de Park
Resumen en portugués
Este trabalho apresenta o desenvolvimento de algoritmos para a análise automática de eventos de sobrecorrente em sistemas elétricos de potência. Os algoritmos propostos neste trabalho são baseados em registros de tensões e correntes, efetuados por dispositivos eletrônicos inteligentes (oscilógrafos digitais e/ou relés de proteção) instalados nas redes elétricas, e são capazes de avaliar o estado operativo dessas redes com base nessas informações. Os algoritmos integram um sistema automático de análise de eventos de sobrecorrente, que é capaz de estimar o instante de ocorrência do evento, identificar as fases envolvidas e classificar o tipo de falta por meio de fasores calculados a partir dos seus registros. Além disso, este trabalho apresenta uma comparação entre duas técnicas distintas para o cálculo do fasor (a primeira utiliza a Transformada Discreta de Fourier, com janela de um ciclo, e a segunda é baseada em algoritmos genéticos) e três técnicas distintas para a estimação do instante de ocorrência do evento (a primeira utiliza a transformada de Fourier associada a um filtro digital que implementa uma função densidade de probabilidade, a segunda substitui a transformada de Fourier pelos algoritmos genéticos e a terceira é baseada somente na Transformada de Park). Para a avaliação dos algoritmos desenvolvidos, foram elaboradas simulações de duas redes de distribuição no software ATP Alternative Electromagnetic Transients Program, além de dados reais de sistemas de distribuição de concessionárias brasileiras.
Título en inglés
Algorithms for automatic analysis of faults in electrical power systems.
Palabras clave en inglés
Automated fault analysis
Distribution network
Genetic algorithm
Park transform
Resumen en inglés
This work presents the development of algorithms for the automatic analysis of overcurrent events in electrical power systems. The algorithms proposed in this paper are based on data of voltages and currents recorded by intelligent electronic devices (digital oscillographs and / or protection relays) installed in electrical networks, which can evaluate the operating state of these networks based on this information. The algorithms incorporate an automatic system for overcurrent analysis, which is able to estimate the time of occurrence of the event, identify the steps involved and classify the fault type using the phasors of voltages and currents calculated from their records. Furthermore, this work presents a comparison between two distinct techniques for phasor calculation (the first one uses the Discrete Fourier Transform, with a cycle window, and the second one is based on genetic algorithms) and three distinct techniques to estimate the time of the occurrence of the event (the first is based on Fourier Transform and a digital filter that implements a probability density function, the second one replaces Fourier transform by Genetic Algorithm and the third one is based on Park transform). For the evaluation of the developed algorithms, cases from two distribution network model have been generated in the ATP software - Alternative Electromagnetic Transients Program, additionally, actual data from distribution Brazilian utilities systems were also analyzed by the developed algorithm.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-01-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.