• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.3.2010.tde-20102010-123221
Documento
Autor
Nome completo
André Fernando Lourenço de Souza
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2010
Orientador
Banca examinadora
Furuie, Sérgio Shiguemi (Presidente)
Sales, Fernando José Ribeiro
Santos, Marcelo dos
Título em português
Abordagens para a segmentação de coronárias em ecocardiografia.
Palavras-chave em português
Ecocardiografia
Fuzzy-connectedness
Processamento digital de imagens
Segmentação de imagens
Resumo em português
A Ecocardiografia continua sendo a técnica de captura de imagens mais promissora, não-invasiva, sem radiação ionizante e de baixo custo para avaliação de condições cardíacas. Porém, é afetada consideravelmente por ruídos do tipo speckle, que são difíceis de serem filtrados. Por isso fez-se necessário fazer a escolha certa entre filtragem e segmentador para a obtenção de resultados melhores na segmentação de estruturas. O objetivo dessa pesquisa foi estudar essa combinação entre filtro e segmentador. Para isso, foi desenvolvido um sistema segmentador, a fim de sistematizar essa avaliação. Foram implementados dois filtros para atenuar o efeito do ruído speckle - Linear Scaling Mean Variance (LSMV) e o filtro de Chitwong - testados em imagens simuladas. Foram simuladas 60 imagens com 300 por 300 pixels, 3 modelos, 4 espessuras e 5 níveis de contrastes diferentes, todas com ruído speckle. Além disso, foram feitos testes com a combinação de filtros. Logo após, foi implementado um algoritmo de conectividade Fuzzy para fazer a segmentação e um sistema avaliador, seguindo os critérios descritos por Loizou, que faz a contagem de verdadeiro-positivos (VP) e falso-positivos (FP). Foi verificado que o filtro LSMV é a melhor opção para segmentação por conectividade Fuzzy. Foram obtidas taxas de VP e FP na ordem de 95% e 5%, respectivamente, e acurácia em torno de 95%. Para imagens ruidosas com alto contraste, aplicando a segmentação sem filtragem, a acurácia obtida foi na ordem de 60%.
Título em inglês
Approaches for coronary segmentation in echocardiography.
Palavras-chave em inglês
Digital image processing
Echocardiography
Fuzzy-connectedness
Image segmentation
Resumo em inglês
The echocardiography is the imaging technique that remains most promising, noninvasive, no ionizing radiation and inexpensive to assess heart conditions. On the other hand, is considerably affected by noises, such as speckle, that are very difficult to be filtered. That is why it is necessary to make the right choice of filter and segmentation method to obtain the best results on image segmentation. The goal was evaluate this filter and segmentation method combination. For that, it was developed a segmentation system, to help the assessment. Two filters were implemented to mitigate the effect of speckle noise Linear Scaling Mean Variance (LSMV) and the filter presented by Chitwong - to be tested in simulated images. We simulated 60 images, with size 300 by 300 pixels, 3 models, 4 thicknesses and 5 different levels of contrast, all with speckle noise. In addition, tests were made with a combination of filters. Furthermore, it was implemented a Fuzzy Connectedness algorithm and an evaluation system, following the criteria described by Loizou, which makes the true positives (TP) and false positives (FP) counting. It was found that the LSMV filter is the best option for Fuzzy Connectedness. We obtained rates of TP and FP of 95% and 5% using LSMV, and accuracy of 95%. Using high contrast noisy images, without filtering, we obtained the accuracy in order of 60%.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2010-12-23
 
AVISO: O material descrito abaixo refere-se a trabalhos decorrentes desta tese ou dissertação. O conteúdo desses trabalhos é de inteira responsabilidade do autor da tese ou dissertação.
  • Souza, A F L, e Furuie, S.S. Investigação de filtros adaptativos em imagens ecocardiográficas para segmentação de estruturas. In XIV Congresso Brasileiro de Física Médica, Sao Paulo, 2009. Anais do XIV Congresso Brasileiro de Física Médica., 2009.
  • Souza, A F L, LAGE, Danilo Meneses, e Furuie, S.S. Coronary Segmentation from Echocardiography using Fuzzy Connectedness. In Workshop de Dissertações e Teses, SIBGRAPI 2009, Rio de Janeiro, 2009. Anais do Workshop de Dissertações e Teses, SIBGRAPI 2009., 2009.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.