Tesis Doctoral
DOI
https://doi.org/10.11606/T.3.2017.tde-05102017-100114
Documento
Autor
Nombre completo
Henrique Takachi Moriya
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2003
Director
Tribunal
Moraes, Jose Carlos Teixeira de Barros (Presidente)
Amato, Marcelo Britto Passos
Giannella Neto, Antonio
Martins, Milton de Arruda
Silva, José Felício da
Título en portugués
Contribuições não-lineares e aproximação no domínio do tempo do modelo de fase constante na mecânica respiratória em camundongos.
Palabras clave en portugués
Bioengenharia
Engenharia Biomédica
Mecânica respiratória
Modelo de fase constante
Sistema respiratório
Resumen en portugués
A avaliação das propriedades mecânicas do sistema respiratório é tipicamente realizada oscilando-se um fluxo nos pulmões através da traquéia, medindo-se a pressão resultante gerada na traquéia e relacionando-se os dois sinais em termos de alguns modelos matemáticos. Se o sinal de fluxo de perturbação tem seu espectro em banda larga e não apresenta uma amplitude muito elevada, assume-se que o sistema respiratório está se comportando de forma linear e calcula-se sua impedância de entrada. Alternativamente, alguns pesquisadores tem utilizado sinais de fluxo que apresentam um espectro em banda estreita, mas com altos valores de amplitude, e aplicam modelos paramétricos não-lineares para quantificar as relações entre fluxo e pressão. Pouco tem sido feito, entretanto, para considerar dados relativos ao sistema respiratório quando a excitação é de banda larga e o sistema reflete não-linearidades. Nesta pesquisa, esta categoria de dados foi considerada realizando-se experimentos com camundongos. Para interpretar estes dados, desenvolveu-se uma aproximação no domínio do tempo de um modelo muito empregado para descrever a impedância respiratória de entrada. Este modelo foi então estendido para incluir termos de resistência e elastância não-lineares. Descobriu-se que o modelo com termo de elastância não-linear estima melhor os dados experimentais quando amplitudes altas são utilizadas, relativamente ao modelo linear e ao modelo com termo resistivo não-linear. Este modelo pode também ser útil para detecção de hiperinsuflação dos pulmões durante a ventilação mecânica.
Título en inglés
Non-linear contributions and time domain approximation of the constant phase model in mice respiratory
Palabras clave en inglés
Biomedical engineering
Constant phase model
Respiratory mechanics
Resumen en inglés
The assessment of the mechanical properties of the respiratory system is typically done by oscillating flow into the lungs via the trachea, measuring the resulting pressure generated at the trachea, and relating these two signals to each other in terms of some suitable mathematical model. If the perturbing flow signal is broadband and not too large in amplitude, linear behavior is usually assumed and the input impedance calculated. Alternatively, some researchers have used flow signals that are narrow band but large in amplitude, and invoked nonlinear lumped-parameter models to account for the relationship between flow and pressure. There has been little attempt, however, to deal with respiratory data that is both broadband and reflective of system nonlinearities. In the present study, it was collected such data from mice. To interpret these data, it was first developed a time-domain approximation to a widely used model of respiratory input impedance. It was then extended this model to include nonlinear resistive and elastic terms. It was found that the nonlinear elastic term fit the data better than the linear model or the nonlinear resistance model when amplitudes were large. This model may also be useful for detecting over inflation of the lung during mechanical ventilation.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2017-10-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.