Título em português
Desenvolvimento de microssensores MEMS, visando implantação in vivo para o estudo da fadiga muscular.
Palavras-chave em português
Microagulhas
Microsensores
Microsensores eletroquímicos
Sensores
Sistemas microeletromecânicos
Resumo em português
Na presente pesquisa, foram projetadas e fabricadas matrizes de microeletrodos através das técnicas da microeletrônica e MEMS. Sobre o silício microusinado, com formato de microagulhas (espessura de 100 m), há 3 pares de eletrodos, sendo um eletrodo de referência (Ag) e um eletrodo de trabalho (Au), que podem ser utilizadas para estudos in vivo. Os eletrodos de ouro foram testados, através da voltametria cíclica, em solução de ferricianeto de potássio e apresentaram: (i) ocorrência do processo faradico nas características E1/2 ~ 0,25 V da redução de ferricianeto; (ii) baixa histerese; e (iii) estabilização da corrente limite. Os microelétrodos, também apresentaram boa resposta em solução de ácido sulfúrico, exibindo os picos de característica de oxidação (Ep = 1,5 V) e redução (Ep = 0,9 V) das superfícies de ouro. Foi realizado o processo amperométrico aplicando um potencial E = -0.8V por 600 s, em seguida inicia-se 50 ciclos na voltametria cíclica variando a tensão com passo de 100 mV/s em solução [Ir(COO)2(OH)4]2- pH (10,5), para a deposição do filme de IrOx, que deixa o microelétrodo de Au sensível ao pH. Utilizando solução 0,1 mol/L de PBS (pH 7.0) e variação v = 100 mV/s, antes e depois da deposição do filme de IrOx, foi possível verificar que os dispositivos são sensíveis a variação de pH. Foram realizadas medições de OCP em 0,1 mol/L de PBS com diferentes valores de pH, com base nos valores de tensão foi possível traçar uma reta que pode ter inclinações variando de -59 a -90 mV por unidade de pH a temperatura ambiente.
Título em inglês
Development of mems microsensors, aiming in vivo implantation for the study of muscular fatigue.
Palavras-chave em inglês
Electrochemical sensor
Implantable electrodes
MEMS
Microelectrodes
Microneedles
Resumo em inglês
In the present study, microelectrode arrays were designed and manufactured using microelectronics and MEMS techniques. On the micromachined silicon, with microneedle format (thickness of 100 m), there are 3 pairs of electrodes, being a reference electrode (Ag) and a working electrode (Au), which can be used for in vivo studies. The gold electrodes were tested, through cyclic voltammetry, in potassium ferricyanide solution and showed: (i) occurrence of the faradic process in the characteristics E1/2 ~ 0.25 V of the ferricyanide reduction; (ii) low hysteresis; and (iii) stabilization of the limit current. The microelectrodes also showed good response in sulfuric acid solution, showing the characteristic oxidation (Ep = 1.5 V) and reduction (Ep = 0.9 V) peaks of the gold surfaces. The amperometric process was carried out by applying a potential E = -0.8V for 600 s, then 50 cycles of cyclic voltammetry were started, varying the voltage with a step of 100 mV/s in solution [Ir(COO)2(OH)4] 2- pH (10.5), for the deposition of the IrOx film, complaining about the pH-sensitive Au microelectrode. Using 0.1 mol/L PBS solution (pH 7.0) and variation v = 100 mV/s, before and after deposition of the IrOx film, it was possible to verify that the devices are sensitive to pH variation. OCP measurements were performed in 0.1 mol/L of PBS with different pH values, based on the voltage values it was possible to draw a straight line that can have slopes ranging from -59 to -90 mV per pH unit at room temperature.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.