Master's Dissertation
DOI
https://doi.org/10.11606/D.3.2014.tde-06032015-145219
Document
Author
Full name
Beatriz Eugenia Sanabria Arenas
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2014
Supervisor
Committee
Aoki, Idalina Vieira (President)
Aquino, Isabella Pacifico
Tôrres, Ricardo Belchior
Title in Portuguese
Avaliação da corrosividade do biodiesel para diferentes metais empregando microeletrodos clássicos e arranjos de microeletrodos
Keywords in Portuguese
aço inoxidável
biodiesel
cobre
corrosão
espectroscopia de impedância eletroquímica
microeletrodos
Abstract in Portuguese
Um dos principais problemas no emprego do biodiesel como combustível de automóveis é a corrosão que ele pode provocar nos motores, devido à facilidade com que pode degradar. A natureza corrosiva do biodiesel é relacionada com a presença de água, ácidos graxos livres, ions metálicos, impurezas, a incidência da luz, a temperatura e a presença de insaturações na cadeia de alquil ésteres. Na atualidade existem poucos trabalhos na literatura sobre a corrosão dos metais em contato com biodiesel e a maioria deles têm um enfoque mais qualitativo que quantitativo. O maior desafio para avaliar a corrosividade do biodiesel mediante técnicas eletroquímicas é sua baixa condutividade. A espectroscopia de impedância eletroquímica (EIE) é uma técnica sensível que tem sido empregada para estudar meios resistivos como o etanol, por muitos anos. No entanto, os experimentos são difíceis assim como a análise dos resultados, principalmente pelo desenvolvimento da queda ôhmica no meio, devido à alta resistividade do meio ao fluxo da corrente elétrica. Os microeletrodos têm sido empregados em várias pesquisas em eletroquímica e têm apresentado algumas vantagens com respeito aos eletrodos de tamanhos convencionais. O principal benefício é a redução da queda ôhmica em meios resistivos, devido às baixas correntes registradas. No presente trabalho foi avaliada a corrosão do cobre e do aço inoxidável, os quais se encontram presentes no circuito de combustível dos motores, quando entram em contato com o biodiesel obtido a partir do óleo de soja (B100) e etanol. A avaliação foi feita mediante técnicas eletroquímicas com auxilio dos microeletrodos clássicos e na forma de arranjos (de 25 m de diâmetro), sem adição de eletrólito suporte. Adicionalmente, os resultados foram correlacionados com as mudanças nas propriedades fisicoquímicas do biodiesel (viscosidade, teor de água, teor de acidez e estabilidade oxidativa) e com ensaios gravimétricos segundo a norma ASTM G31. Os ensaios de impedância eletroquímica com os microeletrodos clássicos e os arranjos de microeletrodos mostraram duas constantes de tempo e foi possível demostrar que a constante em altas frequências está relacionada com a qualidade do biodiesel, enquanto que a constante nas baixas frequências é uma resposta da interface metal-biodiesel. A viscosidade e o teor de umidade aumentaram com a degradação do biodiesel e a estabilidade oxidativa diminuiu na mesma proporção independentemente do metal que estava em contato com o biocombustível. A presença de defeitos nos arranjos de microeletrodos obtidos por fotolitografia é um problema importante e é preciso estar sempre atento para evitar resultados equivocados. A voltametria cíclica se mostrou como técnica quantitativa para caracterizar e controlar a área exposta dos microeletrodos simples e em arranjos. Finalmente se corroborou com os ensaios eletroquímicos, a maior velocidade de corrosão para o cobre obtida nos ensaios gravimétricos, comparada à do aço inoxidável.
Title in English
Evaluation of biodiesel corrosiveness for diferent metals using classic microelectrodes and arrangements of microelectrodes
Keywords in English
biodiesel
copper
corrosion
electrochemical impedance spectroscopy
microelectrodes
stainless steel
Abstract in English
One of the most relevant aspects related with the use of biodiesel in automobile motors is its corrosivity, due to its susceptibility to oxidation reactions. The corrosive nature of biodiesel is related with the presence of water, free fatty acids, metallic ions, impurities, incidence of light, temperature, as well as the insaturation degree of the main chain of the alkyl esters. Currently there are few works in literature about corrosion of metals in contact with biodiesel, and most of them have more a qualitative than a quantitative focus. The main issue for electrochemical studies in biodiesel is its low conductivity. Electrochemistry impedance spectroscopy (EIS) is a sensitive technique that has been used for studying resistive media like ethanol for many years. However the experiments are difficult and the results are complex to understand, mainly because of the ohmic drop developed in this media due to the inherent solution resistance to the flow of electrical current. Microelectrodes have been used in many researches in electrochemistry showing some advantages with respect to conventional electrodes. The principal benefit is the reduction of the ohmic drop in resistive media, due to its negligible value when small currents are registered. In this work corrosiveness of copper and stainless steel which are present in fuel circuit of an automobile motor was evaluated when they come in contact with biodiesel, obtained from soybean oil and ethanol (B100). The evaluation was made using classic microelectrodes and arrays of microelectrodes (25m diameter) without addition of supporting electrolyte. Aditionally the results were correlated with the changes in biodiesel physicochemical properties (viscosity, water content, acid number and oxidation stability) and weight loss tests according to ASTM G31. The electrochemical results with classic microeletrodes and arrays of microelectrodes showed two time constants and it was demonstrated that the time constant at high frequencies is related with biodiesel quality, while the time constant at low frequencies is due to the response of metal-biodiesel interface. The viscosity and water content increased with biodiesel degradation and oxidation stability decrease in the same proportion independently of the metal in contact with biofuel. The presence of defects in the microelectrodes arrays obtained by photolitography is an important issue and the researcher must be atempt to them to avoid equivocated results. Cyclic voltammetry has shown to be a useful technique to characterize and control the exposed are in microlectrodes and their arrays. Finally, the electrochemical measurements corroborate the higher corrosion rate for copper obtained from weight loss tests compaired to corrosion rate for stainless steel.
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2015-03-09