Fernando Stancato
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 1992
Director
Tribunal
Pimenta, Marcos de Mattos (Presidente)
Pacheco, Claudio Roberto de Freitas
Silvares, Otavio de Mattos
Título en portugués
Fontes térmicas em cabines de veículos automotivos, sua avaliação e efeito no ambiente interior.
Palabras clave en portugués
Simulação
Veículos automotores
Resumen en portugués
Foi desenvolvido um programa para a simulação de cargas térmicas em cabines de veículos automotivos. Foram feitas experiencias de campo para a avaliação das rotinas de cálculo de carga térmica por condução de paredes, vidros, compartimento de motor e de cálculo de radiação solar. O programa calcula também as cargas térmicas referentes a pessoas, admissão de ar externo e motores e ventiladores internos. O programa apresentou bons resultados com uma precisão menor que 5%. Foram feitos cálculos de cargas térmicas para situação de verão e inverno típicos. Na situação de verão, estudou-se a importância da rota, horário, pintura e cor de vidros nas cargas térmicas de condução e radiação solar pelos vidros. Rotas e horários diferentes podem variar estas cargas em até 225% e cores claras e vidros escuros as podem reduzir em ate 30%.
Título en inglés
Untitled in english
Palabras clave en inglés
Auto-vehicles
Simulation
Resumen en inglés
A mathematical simulation model was developed to calculate the cooling loads in a cab. Fied experiments were conducted do avaliate the conduction cooling loads from walls, glasses, firewall and the solar radiation model. Precision less then 5% were gotten between model results and experimental data. Cooling loads from summer and winter tipical situations were avaliated. In the summer situation, studies of the effects of the orientation of the cab, the time, the external paint and the tinto f the glass in changing the conduction and solar radiation cooling loads, were conducted. Cab orientation and the time can change this cooling loads by 225% and light-colored paint and tinted glasses can reduce this cooling loads by 30%.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2024-03-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.