• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.3.2001.tde-21022024-144621
Documento
Autor
Nome completo
Edir Branzoni Leal
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2001
Orientador
Banca examinadora
Ortiz, Jayme Pinto (Presidente)
Lima, Raúl González
Silva, Domingos Guerino
Título em português
Simulador hidrodinâmico para estudos "in vitro" do sistema cardiovascular.
Palavras-chave em português
Sistema cardiovascular (Simulação)
Resumo em português
O presente trabalho refere-se ao aperfeiçoamento e otimização de um simulador cardiovascular para a avaliação de vasos sangüíneos. O simulador é constituído basicamente de duas partes: uma unidade central de fluxo pulsátil e pressão para geração de uma onda pulsátil e outra modular onde ocorrerão os diversos testes dos vasos sangüíneos. Os segmentos utilizados foram obtidos por meio de procedimento cirúrgico de ponte de safena e cirurgia de varizes. Esses segmentos foram cuidadosamente retirados e após a escolha do médico, as partes remanescentes do segmento vascular que apresentava boa condição, foi utilizada no simulador. A calibração foi realizada antes do teste de ruptura da veia. Com o auxílio de um fluxômetro eletromagnético, manômetros do tipo Bourdon, foi possível obter-se os valores de vazão e pressão na seção de teste. Os valores de pressão alcançados para a ruptura das veias são da ordem de 300 kPa ou maior, comprovando a alta resistência da estrutura da parede da veia.
Título em inglês
Untitled in english
Palavras-chave em inglês
Cardiovascular system (Simulation)
Resumo em inglês
The present work refers both to the perfectioning and optimization of a cardiovascular simulator for the evaluation of blood vessels. The simulator consists basically of two parts: a central unit of pulsing flux and pressure to generate a wave pulse and a modular unit in which the various blood vessel tests will occur. The vein segments used were obtained from surgery procedure of Saphena overpass and varix surgery. These segments were carefully removed during surgeries and after the choice of surgeons, the reminiscent parts of vascular segment presenting a good shop were used in the simulator. The calibration system was performed before the system of vein rupture test. With the aid of an electromagnetic flow meter, Bourdon manometers, it was possible to get results of volumetric flux and pressure in the test section. The pressure values reached for vein segment ruptures are on the order of 300 kPa or more, proving the high resistance of the vein wall structure.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2024-02-21
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.