Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2001.tde-21022024-144621
Documento
Autor
Nombre completo
Edir Branzoni Leal
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2001
Director
Tribunal
Ortiz, Jayme Pinto (Presidente)
Lima, Raúl González
Silva, Domingos Guerino
Título en portugués
Simulador hidrodinâmico para estudos "in vitro" do sistema cardiovascular.
Palabras clave en portugués
Sistema cardiovascular (Simulação)
Resumen en portugués
O presente trabalho refere-se ao aperfeiçoamento e otimização de um simulador cardiovascular para a avaliação de vasos sangüíneos. O simulador é constituído basicamente de duas partes: uma unidade central de fluxo pulsátil e pressão para geração de uma onda pulsátil e outra modular onde ocorrerão os diversos testes dos vasos sangüíneos. Os segmentos utilizados foram obtidos por meio de procedimento cirúrgico de ponte de safena e cirurgia de varizes. Esses segmentos foram cuidadosamente retirados e após a escolha do médico, as partes remanescentes do segmento vascular que apresentava boa condição, foi utilizada no simulador. A calibração foi realizada antes do teste de ruptura da veia. Com o auxílio de um fluxômetro eletromagnético, manômetros do tipo Bourdon, foi possível obter-se os valores de vazão e pressão na seção de teste. Os valores de pressão alcançados para a ruptura das veias são da ordem de 300 kPa ou maior, comprovando a alta resistência da estrutura da parede da veia.
Título en inglés
Untitled in english
Palabras clave en inglés
Cardiovascular system (Simulation)
Resumen en inglés
The present work refers both to the perfectioning and optimization of a cardiovascular simulator for the evaluation of blood vessels. The simulator consists basically of two parts: a central unit of pulsing flux and pressure to generate a wave pulse and a modular unit in which the various blood vessel tests will occur. The vein segments used were obtained from surgery procedure of Saphena overpass and varix surgery. These segments were carefully removed during surgeries and after the choice of surgeons, the reminiscent parts of vascular segment presenting a good shop were used in the simulator. The calibration system was performed before the system of vein rupture test. With the aid of an electromagnetic flow meter, Bourdon manometers, it was possible to get results of volumetric flux and pressure in the test section. The pressure values reached for vein segment ruptures are on the order of 300 kPa or more, proving the high resistance of the vein wall structure.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2024-02-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.