• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2002.tde-19092007-000212
Documento
Autor
Nombre completo
Guilherme Araújo Lima da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2002
Director
Tribunal
Silvares, Otavio de Mattos (Presidente)
Paiva, Marco Antonio Soares de
Zerbine, Euryale Jorge Godoy de Jesus
Título en portugués
Modelagem e simulação da operação de sistema antigelo eletrotérmico de um aerofólio.
Palabras clave en portugués
Aerofólios
Aeronaves
Antigelo
Camada limite
Formação de gelo
Proteção contra gelo
Simulação térmica
Transferência de calor
Transferência de massa
Transição laminar-turbulenta
Resumen en portugués
No presente trabalho foi implementado um modelo matemático para simular o sistema antigelo eletrotérmico de um aerofólio. Por meio do programa ONERA2D simulou-se o escoamento potencial completo com velocidade 44,7 m/s (100 mph) e 89,4 m/s (200 mph) em torno de um aerofólio perfil NACA0012 de corda 0,914 m (3 pés) com ângulo de ataque de 0°, e calculou-se a eficiência de coleta local de gotículas de água com diâmetro mediano volumétrico de 20 μm. Foram simuladas quatro condições de teste com diferentes distribuições de fluxo de calor nos aquecedores elétricos do sistema antigelo. O modelo previu a distribuição de temperaturas na superfície sólida do aerofólio e no filme de água líquida, e as distribuições de fluxo de água líquida sobre a superfície do aerofólio ("runback water") e de coeficiente de transferência de calor por convecção de calor entre a superfície do aerofólio e o escoamento gasoso. Os resultados da simulação obtidos com o modelo foram comparados com resultados experimentais da NASA e os resultados numéricos dos programas LEWICE/ANTICE (EUA) e CANICE (Canada). Para as regiões molhadas pelo filme de água líquida, obteve-se um desvio máximo de temperatura de 2,6°C entre os resultados do presente modelo e o resultados experimentais. Para as regiões secas, onde não existe o filme de água líquida sobre a superfície do aerofólio, obteve-se um desvio de máximo de temperatura de 8°C. As previsões para distribuição de vazão de "runback", posição do término do filme de água líquida foram comparadas com os resultados do programa LEWICE/ANTICE. O modelo desenvolvido simula com adequada aproximação os efeitos da transferência de calor e de massa por convecção entre a superfície não-isotérmica do aerofólio ou do filme de água líquida e o escoamento gasoso, bem como os efeitos da transição entre o escoamento laminar e o turbulento na camada limite dinâmica e térmica e ainda a influência do escoamento do filme de água líquida sobre o desempenho do sistema de antigelo do aerofólio.
Título en inglés
Modeling and simlulation of an electro-thermal airfoil anti-ice system operation.
Palabras clave en inglés
Aircraft
Airfoil
Anti-ice
Boundary layer
Heat transfer
Ice protection
Icing
Laminar-turbulent transition
Mass transfer
Thermal simulation
Resumen en inglés
An electro-thermal anti-ice system was simulated with a mathematical model developed in the present work. A 44.7 m/s (100 mph) and 89.4 m/s (200 mph) full potential flow around a 0.914 m (3 ft) chord NACA0012 airfoil with 0° angle of attack and the local water catch efficiency of 20 μm median volumetric diameter droplets impingement were calculated by the numerical code ONERA2D. Four test conditions were simulated with four different heat flux distributions of the anti-ice system according to the experimental work developed at NASA. The model predicted distributions of solid surface and liquid water film temperatures, runback water flow and convection heat transfer coefficient between airfoil or water surface and gaseous flow. The simulated results obtained by the mathematical model developed were compared to NASA experimental results and the ones predicted by the numerical codes LEWICE/ANTICE (US) and CANICE (Canada). For the regions wetted by the water film, the present model provided 2.6°C maximum temperature deviations between the predicted results and experimental data. For the dry regions, where there is no liquid water on the airfoil surface, an 8°C maximum temperature deviation was obtained. The runback flow and water film ending point position were compared to LEWICE/ANTICE numerical results. The developed model predicts adequately the convection heat and mass transfer effects between the non-isothermal airfoil or liquid water film surface and the gaseous flow, as well the effects of laminar to turbulent flow transition within dynamic and thermal boundary layer and the influence of the liquid water film flow on the anti-ice system performance.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
silva_msc.pdf (10.49 Mbytes)
Fecha de Publicación
2007-09-25
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.