Disertación de Maestría
DOI
https://doi.org/10.11606/D.3.2003.tde-05032024-101048
Documento
Autor
Nombre completo
Antonio Gonçalves do Curral
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2003
Director
Tribunal
Ortiz, Jayme Pinto (Presidente)
Assunção, João Vicente de
Oliveira Junior, Silvio de
Título en portugués
Avaliação de impacto ambiental produzido por usinas termelétricas com enfoque na poluição atmosférica.
Palabras clave en portugués
Impactos ambientais
Poluição atmosférica
Usinas termoelétricas
Resumen en portugués
O presente trabalho avalia a poluição ambiental produzida por usinas termelétricas, com enfoque na poluição atmosférica, sendo desenvolvido através do Estudo de Caso de uma usina operando em ciclo combinado. A modelagem para a estimativa da qualidade do ar é efetuada com o modelo gaussiano ISC-ST - "Industrial Source Complex - Short Term" - versão 3, referendado pela "Environmental Protection Agency" dos Estados Unidos - USEPA. São feitas estimativas de taxas de emissão de poluentes, a partir dos fatores de emissão constantes no "Compilation of Air Pollutant Emission Factors, Volume 1-Stationary Point and Areas Sources. Publication No. AP-42 da USEPA". A caracterização do relevo da região de influência é efetuada através de arquivo topográfico, no formato ASCII, gerado a partir de plantas topográficas, divididas em quadriculas contendo as coordenadas cartesianas e a máxima altitude. Como dados meteorológicos, utilizam-se arquivos, no formato ASC II, obtidos de dados da estação meteorológica do Aeroporto de Congonhas (número 83780, da rede mundial de meteorologia), relativos aos anos de 1997 e 1998, compatíveis com os dados utilizados por empresa Consultora, em estudo de dispersão efetuado anteriormente. Da análise das curvas de isoconcentração para os diversos poluentes estudados são identificadas as regiões mais críticas, quanto à alteração da qualidade do ar. São analisadas as concentrações nos mesmos receptores discretos analisados pela Consultora. O trabalho é concluído através de uma análise crítica dos resultados, objetivando contribuir com a área acadêmica e com os órgãos ambientais.
Título en inglés
Untitled in english
Palabras clave en inglés
Atmospheric pollution
Environmental impacts
Thermoelectric plants
Resumen en inglés
The present work evaluates the environmental pollution produced by power plants, with focus in the atmospheric pollution, being developed through the Study of Case of a power plant operating in combined cycle. The simulation for the estimate of the air quality is performed with the gaussian model ISC-ST - "Industrial Source Complex" - "Short Term" - version 3, referenced by " Environmental Protection Agency" of the United States - USEPA. Estimates are done for the rates of pollutants emission, starting from the constant emission factors in the "Compilation of Air Pollutant Emission Factors, Volume 1-Stationary Point and Areas Sources. Publication No. AP-42 of USEPA". The relief's characterization of the influence area is made through topographical file, in the format ASCII, generated through topographical plants, divided in squares contends the Cartesians coordinates and the maximum altitude. Like meteorological data, files are used, in the format ASC II, obtained of data of the meteorological station in the Congonhas's Airport (number 83780, of the world net of meteorology), relative to the years of 1997 and 1998, compatible with the data used by the Consultant. Of the analysis of the same concentration curves for the several studied pollutants are identified the most critical areas, with relationship to the alteration of the air quality. The concentrations are analyzed in the same discreet receivers analyzed by the Consultant. The work is concluded through a critical analysis of the results; objectiving to contribute with the academic area and with the environment organs.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2024-03-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.