Título em português
Análise comparativa de técnicas de fixação interna rígida em três diferentes osteotomias sagitais do ramo mandibular: estudo biomecânico
Palavras-chave em português
Avanço mandibular
Fixação interna rígida
Osteotomia sagital do ramo mandibular
Resumo em português
A Osteotomia Sagital do Ramo Mandibular é amplamente utilizada para tratamento de deformidades mandibular. Desde que foi inicialmente descrita diversas foram as modificações propostas para reduzir riscos e desvantagens, e com a introdução da fixação interna, diferentes técnicas têm sido estudadas para estabilizar os segmentos distais e proximais. Na literatura vigente não há um consenso para as fixações a serem utilizadas nas osteotomias Lingual short Split e Osteotomia Oblíqua Anterior, assim, o objetivo deste trabalho foi avaliar comparativamente a resistência mecânica de 3 tipos de fixação para cada uma das osteotomias: Lingual short Split, Osteotomia Oblíqua Anterior e a Osteotomia Sagital Convencional em avanços mandibulares lineares de 5 mm. Para o estudo foram confeccionadas 90 réplicas de hemimandíbulas com Osteotomia Sagital do Ramo Mandibular à base de poliuretano sintético (Convencional, Lingual Short Split e Oblíqua Anterior). As hemimandíbulas pertencentes a cada desenho de osteotomia foram divididas igualmente em 3 grupos de fixação (n=10) Parafusos Bicorticais; Placa; e Híbrida. As hemimandíbulas foram submetidas a testes mecânicos compressivos para simular a força mastigatória em máquina de testes universal. O equipamento foi programado para verificar a resistência em Newtons (N) durante o carregamento progressivo a uma velocidade de deslocamento de 1 mm/min até um deslocamento máximo de 10 mm do segmento distal, ou até o rompimento do sistema de fixação do espécime. Durante a realização foi observado que a primeira área de fragilidade e consequentemente a primeira região de falha foi a área da fixação do parafuso bicortical quando realizada a fixação híbrida. Na fixação com 3 parafusos bicorticais o sistema evoluiu com maior força, porém resistiu a um menor deslocamento com fratura da cortical óssea acima dos parafusos no segmento proximal. A osteotomia convencional suportou maiores cargas, e a fixação híbrida foi a que suportou maiores valores de força.
Título em inglês
Comparative analysis of rigid internal fixation techniques in three different bilateral sagittal split osteotomies - biomechanical study
Palavras-chave em inglês
Mandibular advancement
Rigid internal fixation
Sagittal split ramus osteotomy
Resumo em inglês
Bilateral sagittal split osteotomy is widely used for the treatment of mandibular deformities. Since it was initially described, several modifications have been proposed to reduce risks and disadvantages, and with the introduction of internal fixation, different techniques have been studied to stabilize the distal and proximal segments. In the current literature, there is no consensus for the fixations to be used in the Lingual short Split and Anterior Oblique Osteotomy, thus, the objective of this study was to comparatively evaluate the mechanical resistance of 3 types of fixation for each of the osteotomies: Lingual Short Split, Anterior Oblique Osteotomy and Conventional Sagittal Osteotomy in 5 mm linear mandibular advancements. For the study, 90 replicas of hemimandibles were made with Sagittal Osteotomy based on synthetic polyurethane (Conventional, Lingual Short Split and Anterior Oblique). The hemimandibles belonging to each osteotomy design were equally divided into 3 osteosynthesis groups (n=10) Bicortical Screws; Plate; and Hybrid. The hemimandibles were submitted to compressive mechanical tests to simulate masticatory force in a universal testing machine. The equipment was programmed to check the resistance in Newtons (N) during progressive loading at a displacement speed of 1 mm/min until a maximum displacement of 10 mm of the distal segment, or until the rupture of the system sample. During the execution, it was observed that the first area of fragility and consequently the first region of failure was the area of fixation of the bicortical screws when performing the hybrid fixation. In fixation with 3 bicortical screws, the system evolves with greater force, but resisted a smaller displacement with fracture of the cortical bone above the screws in the proximal segment. The conventional osteotomy supported greater loads, and the hybrid fixation was those that supported the highest force values.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Há arquivos retidos devido a solicitação (publicação de dados, patentes ou diretos autorais).
Data de Liberação
2025-05-18
Data de Publicação
2023-11-09
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.