• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.25.2023.tde-06112023-164727
Documento
Autor
Nombre completo
Gustavo Zanna Ferreira
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2023
Director
Tribunal
Gonçales, Eduardo Sanches (Presidente)
Sverzut, Cassio Edvard
Iwaki Filho, Liogi
Sant Ana, Eduardo
Título en portugués
Análise comparativa de técnicas de fixação interna rígida em três diferentes osteotomias sagitais do ramo mandibular: estudo biomecânico
Palabras clave en portugués
Avanço mandibular
Fixação interna rígida
Osteotomia sagital do ramo mandibular
Resumen en portugués
A Osteotomia Sagital do Ramo Mandibular é amplamente utilizada para tratamento de deformidades mandibular. Desde que foi inicialmente descrita diversas foram as modificações propostas para reduzir riscos e desvantagens, e com a introdução da fixação interna, diferentes técnicas têm sido estudadas para estabilizar os segmentos distais e proximais. Na literatura vigente não há um consenso para as fixações a serem utilizadas nas osteotomias Lingual short Split e Osteotomia Oblíqua Anterior, assim, o objetivo deste trabalho foi avaliar comparativamente a resistência mecânica de 3 tipos de fixação para cada uma das osteotomias: Lingual short Split, Osteotomia Oblíqua Anterior e a Osteotomia Sagital Convencional em avanços mandibulares lineares de 5 mm. Para o estudo foram confeccionadas 90 réplicas de hemimandíbulas com Osteotomia Sagital do Ramo Mandibular à base de poliuretano sintético (Convencional, Lingual Short Split e Oblíqua Anterior). As hemimandíbulas pertencentes a cada desenho de osteotomia foram divididas igualmente em 3 grupos de fixação (n=10) Parafusos Bicorticais; Placa; e Híbrida. As hemimandíbulas foram submetidas a testes mecânicos compressivos para simular a força mastigatória em máquina de testes universal. O equipamento foi programado para verificar a resistência em Newtons (N) durante o carregamento progressivo a uma velocidade de deslocamento de 1 mm/min até um deslocamento máximo de 10 mm do segmento distal, ou até o rompimento do sistema de fixação do espécime. Durante a realização foi observado que a primeira área de fragilidade e consequentemente a primeira região de falha foi a área da fixação do parafuso bicortical quando realizada a fixação híbrida. Na fixação com 3 parafusos bicorticais o sistema evoluiu com maior força, porém resistiu a um menor deslocamento com fratura da cortical óssea acima dos parafusos no segmento proximal. A osteotomia convencional suportou maiores cargas, e a fixação híbrida foi a que suportou maiores valores de força.
Título en inglés
Comparative analysis of rigid internal fixation techniques in three different bilateral sagittal split osteotomies - biomechanical study
Palabras clave en inglés
Mandibular advancement
Rigid internal fixation
Sagittal split ramus osteotomy
Resumen en inglés
Bilateral sagittal split osteotomy is widely used for the treatment of mandibular deformities. Since it was initially described, several modifications have been proposed to reduce risks and disadvantages, and with the introduction of internal fixation, different techniques have been studied to stabilize the distal and proximal segments. In the current literature, there is no consensus for the fixations to be used in the Lingual short Split and Anterior Oblique Osteotomy, thus, the objective of this study was to comparatively evaluate the mechanical resistance of 3 types of fixation for each of the osteotomies: Lingual Short Split, Anterior Oblique Osteotomy and Conventional Sagittal Osteotomy in 5 mm linear mandibular advancements. For the study, 90 replicas of hemimandibles were made with Sagittal Osteotomy based on synthetic polyurethane (Conventional, Lingual Short Split and Anterior Oblique). The hemimandibles belonging to each osteotomy design were equally divided into 3 osteosynthesis groups (n=10) Bicortical Screws; Plate; and Hybrid. The hemimandibles were submitted to compressive mechanical tests to simulate masticatory force in a universal testing machine. The equipment was programmed to check the resistance in Newtons (N) during progressive loading at a displacement speed of 1 mm/min until a maximum displacement of 10 mm of the distal segment, or until the rupture of the system sample. During the execution, it was observed that the first area of fragility and consequently the first region of failure was the area of fixation of the bicortical screws when performing the hybrid fixation. In fixation with 3 bicortical screws, the system evolves with greater force, but resisted a smaller displacement with fracture of the cortical bone above the screws in the proximal segment. The conventional osteotomy supported greater loads, and the hybrid fixation was those that supported the highest force values.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Ha ficheros retenidos debido al pedido (publicación de datos, patentes o derechos autorales).
Fecha de Liberación
2025-05-18
Fecha de Publicación
2023-11-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.