  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.25.2023.tde-29092023-150917
Document
Author
Full name
Letícia Alves de Lima Ferrari
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2023
Supervisor
Committee
Ishikiriama, Bella Luna Colombini (President)
Calvo, Adriana Maria
Fleury, Camila de Assis
Módena, Karin Cristina da Silva
Title in Portuguese
Espectrometria de massas LCMS/MS na quantificação da prostaglandina em amostras de saliva aprimoramento e validação do método
Keywords in Portuguese
LCMS/MS
prostaglandina
saliva
Abstract in Portuguese
Os anti-inflamatórios não esteroidais são fármacos que exercem seu mecanismo de ação por meio da inibição da ação da enzima ciclooxigenase, que sintetiza mediadores inflamatórios, como a prostaglandina 2, para combater os sintomas de dor, febre e inflamação. Desta forma, a quantificação das concentrações de prostaglandinas representa um reflexo da atividade inflamatória e da ação da ciclooxigenase nos tecidos humanos. No entanto, não existem na literatura muitos estudos que relatam a quantificação da prostaglandina, especialmente em amostras de saliva um fluido biológico de fácil obtenção, que favorece a avaliação de moléculas como esta, por ser menos invasivas para o paciente, uma vez que para esses estudos são necessárias muitas amostras. Desta forma, este trabalho tem como objetivo avaliar a eficácia do método MEPS LCMS/MS na extração e detecção de PGE2 a partir de amostras de saliva humana e validar essa metodologia a partir de amostras de saliva de acordo com as normas da ANVISA. Para tal, foram coletadas amostras de saliva, antes e após a ingestão do AINE meloxicam, utilizado como ferramenta farmacológica AINES. Estas amostras de saliva foram submetidas à extração da prostaglandina pelo método de microextração por sorvente empacotado (MEPS), por ser mais rápido e fácil de conduzir. Já para a determinação da concentração da prostaglandina presente nas amostras de saliva foi utilizada a cromatografia líquida acoplada ao espectrômetro de massas (LC MS/MS). Notou-se a diminuição dos níveis de prostaglandina E2 após a ingestão do medicamento, esses níveis começam a diminuir até 5 horas, voltando ao normal nas horas seguintes. Nos testes de validação foi possível confirmar a linearidade das amostras, obtendo um coeficiente de correlação de r2= 0,9888791 e a equação linear obtida foi de (x)= 540,783*x+447,083 e nos testes de precisão e exatidão o resultado foi inferior a 15%. Desta forma, a metodologia de extração e quantificação de prostaglandinas a partir de saliva humana testadas, mostraram-se rápidas e eficazes, de acordo com os critérios da ANVISA e podem ser utilizadas com segurança para tal finalidade.
Title in English
LCMS/MS mass spectrometry in the quantification of prostaglandin in saliva samples method improvement and validation
Keywords in English
LCMS/MS
prostaglandin
saliva
Abstract in English
Non-steroidal anti-inflammatory drugs are drugs that exercise their mechanism of action by inhibiting the action of the cyclooxygenase enzyme, which synthesizes inflammatory mediators, such as prostaglandin 2, , to combat symptoms of pain, fever and inflammation. Thus, the quantification of prostaglandin concentrations represents a reflection of the inflammatory activity and the action of cyclooxygenase in human tissues. However, there are not many studies in the literature that report the quantification of prostaglandin, especially in saliva samples - a biological fluid that is easy to obtain, which favors the evaluation of molecules like this one, as it is less invasive for the patient, since for these studies require many samples. Thus, this work aims to evaluate the effectiveness of the MEPS LCMS/MS method in the extraction and detection of PGE2 from human saliva samples and to validate this methodology from saliva samples in accordance with ANVISA standards. . To this end, saliva samples were collected before and after the ingestion of the NSAID meloxicam, used as a pharmacological tool NSAIDs. These saliva samples were subjected to prostaglandin extraction using the packaged sorbent microextraction (MEPS) method, as it is faster and easier to conduct. For the determination of the concentration of prostaglandin present in the saliva samples, liquid chromatography coupled to the mass spectrometer (LC MS/MS) was used. A decrease in prostaglandin E2 levels was noted after ingestion of the drug, these levels begin to decrease up to 5 hours, returning to normal in the following hours. In the validation tests it was possible to confirm the linearity of the samples, obtaining a correlation coefficient of r2= 0.9888791 and the linear equation obtained was (x)= 540.783*x+447.083 and in the precision and accuracy tests the result was lower to 15%. Thus, the methodology for extracting and quantifying prostaglandins from human saliva tested proved to be fast and effective, according to ANVISA criteria and can be safely used for this purpose.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2023-10-03
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI