• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.25.2024.tde-03052024-154348
Documento
Autor
Nome completo
Patrícia Sanches Kerges Bueno
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Bauru, 2024
Orientador
Banca examinadora
Bullen, Izabel Regina Fischer Rubira de (Presidente)
Silva, Guilherme Ferreira da
Abujamra, Roberta Heiffig Handem
Duarte, Marco Antonio Hungaro
Título em português
Acurácia da tomografia computadorizada de feixe cônico e o impacto no tratamento endodôntico em dentes pré-molares inferiores
Palavras-chave em português
microtomografia computadorizada
pré molar inferior
tomografia computadorizada de feixe cônico
Resumo em português
O conhecimento da anatomia interna e externa dos dentes é de fundamental importância para a prática clínica endodôntica. Dentes como os pré molares inferiores (PMI) que apresentam variações em sua anatomia necessitam de exames de imagem de qualidade para que suas estruturas e possíveis variações sejam observadas, prévias ao tratamento. Portanto o objetivo desse trabalho foi comparar a acurácia das imagens de pré molares inferiores na identificação de foraminas acessórias, realizadas por Tomografia Computadorizada de Feixe Cônico (TCFC), bem como o uso de um software para redução de artefato, com as imagens geradas pela Microtomografia Computadorizada (micro-CT), considerada padrão ouro. Foram selecionados 50 dentes PMI, estes foram submetidos a dois equipamentos de tomografia, microtomografia (micro-CT) e tomografia computadorizada de feixe cônico (TCFC). Em cada equipamento foram adquiridas uma imagem de cada dente, e essas imagens compõem o n dessa pesquisa, portanto o n=100 imagens. Através do teste de Bland-Altman obteve-se o resultado da média da diferença (viés), entre os métodos avaliados com o padrão ouro, sendo o viés da TCFC Sirona = 1,24 e do filtro e-Vol DX = 1,48, sendo significativamente diferentes de zero, isso demonstra que nenhum método obteve concordância com o padrão ouro. A acurácia da TCFC foi de 36,5% e do e-Vol DX 30,4%, demostrando que o uso do filtro nesse caso não apresentou melhora. Por fim, através do teste de Friedman, foi possível avaliar qualitativamente os métodos entre si, não havendo diferença significativa entre eles. Concluindo assim, que nenhum método utilizado apresentou resultados semelhantes de acurácia com o micro-CT.
Título em inglês
Accuracy of cone beam computed tomography and the impact on endodontic treatment in mandibular premolar teeth
Palavras-chave em inglês
cone beam computed tomography
mandibular premolar
micro computed tomography
Resumo em inglês
Knowledge of the internal and external anatomy of teeth is of fundamental importance for endodontic clinical practice. Teeth such as mandibular premolars that present variations in their anatomy require quality imaging exams so that their structures and possible variations can be observed, prior to treatment. Therefore, the objective of this work was to compare the accuracy of images of mandibular premolars in identifying accessory foramina, performed by Cone Beam Computed Tomography (CBCT), as well as the use of software to reduce artifact, with the images generated by Microtomography Computerized (micro-CT), considered the gold standard. Fifty mandibular premolars teeth were selected and subjected to two tomography equipment, microtomography (micro-CT) and cone beam computed tomography (CBCT). In each piece of equipment, an image of each tooth was acquired, and these images make up the n of this research, therefore the n=100 images. Using the Bland-Altman test, the result of the mean difference (bias) was obtained between the methods evaluated with the gold standard, with the bias of the CBCT Sirona = 1.24 and the e-Vol DX filter = 1.48, being significantly different from zero, this demonstrates that no method achieved agreement with the gold standard. The accuracy of CBCT was 36.5% and of e-Vol DX 30.4%, demonstrating that the use of the filter in this case did not improve. Finally, using the Friedman test, it was possible to qualitatively evaluate the methods among themselves, with no significant difference between them. In conclusion, no method used presented similar accuracy results with micro-CT.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2024-05-06
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.