• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.25.2012.tde-03042013-153516
Documento
Autor
Nombre completo
Marcelo Lupion Poleti
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2012
Director
Tribunal
Bullen, Izabel Regina Fischer Rubira de (Presidente)
Carreira, Daniela Gamba Garib
Conti, Ana Claudia de Castro Ferreira
Sant'Ana, Eduardo
Sarmento, Viviane Almeida
Título en portugués
Análise de medidas lineares da mandíbula em modelos tridimensionais reformatados a partir da tomografia computadorizada de feixe cônico
Palabras clave en portugués
Diagnóstico por imagem
Imagem tridimensional
Mandíbula
Software
Tomografia computadorizada de feixe cônico
Resumen en portugués
Objetivo: Avaliar a precisão e a acurácia de medidas lineares da mandíbula em modelos tridimensionais gerados a partir da tomografia computadorizada de feixe cônico (TCFC) em dois programas (Dolphin®. Material e Métodos: Dez mandíbulas com marcadores de sílica foram submetidas à TCFC seguindo o protocolo de voxel 0,3 mm do aparelho i-CAT Classic®. Vinte medidas lineares foram realizadas duas vezes, de maneira aleatória, nos modelos tridimensionais nos programas Dolphin®, nos filtros Translúcido e Sólido-1, e InVesalius®. As medidas físicas foram realizadas com um paquímetro digital diretamente nas mandíbulas por um segundo examinador. Análise de variância para medidas repetidas (ANOVA), coeficiente de correlação intraclasse, teste de Bland-Altman e erro absoluto e percentual foram utilizados para avaliar a precisão e a acurácia (p<0,05). Resultados: Alta precisão foi encontrada no programa Dolphin®, filtro Translúcido e Sólido-1 e InVesalius®, com diferença máxima entre as mensurações de 0,27; 0,26 e 0,17 mm, respectivamente. Com relação à acurácia, 10 variáveis no filtro Translúcido; oito no filtro Sólido-1 e 13 no programa inVesalius® foram diferentes estatisticamente em relação as medidas físicas. Porém, 95%, 100% e 90% das medidas apresentaram valores abaixo do valor considerado clinicamente relevante (1 mm) nos filtros Translúcido e Sólido-1 e no programa InVesalius®, respectivamente. Conclusão: Os modelos tridimensionais com marcadores hiperdensos, gerados pelos programas Dolphin®, filtro Translúcido e Sólido-1, e InVesalius® podem ser utilizados com precisão e acurácia para a obtenção de medidas lineares.
Título en inglés
Mandibular linear measurements on 3D CBCT models
Palabras clave en inglés
Cone-Beam Computed Tomography
Diagnostic imaging
Mandible
Software
Three-dimensional image
Resumen en inglés
Objective: The purpose of this study was to determine the accuracy and reliability of mandibular linear measurements obtained from 3-dimensional cone-beam computed tomography (CBCT) scans of dry human mandibles using different software (Dolphin® and InVesalius®). Methods: Ten dry human mandibles were scanned at voxel size of 0.3 mm (i-CAT Classic®). Twenty measurements were made twice, randomized, on 3D model generated by the software Dolphin (filter Translucent and Solid-1) and InVesalius. Subsequently, physical measurements were made using a digital caliper. Analysis of variance for repeated measures (ANOVA), Intraclass correlation (ICC) BlandAltman, absolute and percentage mean error were used for evaluating accuracy and reliability (p<0.05). Results: Excellent reliability values were found for linear measurements from CBCT volume rendering images in all methods (Dolphin Translucent, Solid-1 and InVesalius), with the mean measurement of 0.27; 0.26 and 0.17 mm, respectively. Ten measurement errors for Dolphin Translucent, eight for Solid-1 and 13 for InVesalius were statistically significant different from physical measurements; however, 95%, 100% and 90% of the measurements were, respectively, below the value clinically relevant (1 mm). Conclusion: Linear measurements on 3D model generated by the software Dolphin (Translucent and Solid-1) and InVesalius are reliable and accurate and can be used for linear measurements.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-04-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.