• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.25.2020.tde-22102021-100955
Document
Author
Full name
Ana Cristina Távora de Albuquerque Lopes
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2020
Supervisor
Committee
Mondelli, Rafael Francisco Lia (President)
Bombonatti, Juliana Fraga Soares
Brondino, Nair Cristina Margarido
Vieira, Sergio Roberto
Title in Portuguese
Clareamento com LED violeta associado ou não ao peróxido de carbamida a 37%: estudo clínico randomizado, duplo-cego
Keywords in Portuguese
Clareamento dental
Estética dentária
LED violeta
Sensibilidade da Dentina
Abstract in Portuguese
O presente estudo teve como objetivo avaliar a efetividade do clareamento em consultório com LED violeta associado ou não ao peróxido de carbamida a 37%, sendo consideradas como variáveis de reposta o grau de mudança e estabilidade de cor ao longo de 12 meses e a sensibilidade dental durante 1 mês. Um estudo clínico intervencional, randomizado, duplo-cego para dois protocolos de clareamento em consultório foi conduzido, utilizando-se um sistema de LED violeta associado ou não ao peróxido de carbamida (PC) a 37%. Quarenta participantes, em acordo com os critérios de inclusão e exclusão, foram divididos aleatoriamente em 2 grupos (n=20) segundo o protocolo de clareamento conduzido, em duas sessões, com 7 dias de intervalo: LEDv LED violeta (Bright Max Whitening®, MMOptics) sem gel; LEDv/PC peróxido de carbamida 37% (PowerBleaching Office®, BM4) fotocatalizado com LED violeta. No grupo LEDv, o clareamento na sessão foi realizado por meio de 2 ciclos consecutivos de irradiação de 25 cada (10 x 2 LED + 30 intervalo) com intervalo de 5 minutos entre os ciclos. No grupo LEDv/PC, o gel foi aplicado 5 vezes na sessão de clareamento e fotocatalizado 3 vezes por 2 com intervalos de 30 (730 por aplicação do gel), totalizando 3730 por sessão. A sensibilidade dental foi avaliada com escala visual analógica (VAS) e a efetividade do clareamento em função do grau de mudança e estabilidade de cor (E), com espectrofotômetro. Os dados foram tabulados e submetidos aos testes estatísticos com p<0,05. A análise da sensibilidade dental (VAS) revelou que alguns indivíduos de ambos os grupos apresentaram dor leve (1VAS<4) nos vários intervalos de tempo estudados, tendo sido mais prevalente no grupo LEDv/PC do que no grupo LEDv. Sete dias após a 2ª sessão, apenas 1 indivíduo (5%) em cada grupo ainda apresentou dor leve. Trinta dias após a 2ª sessão, o grupo LEDv não apresentou sensibilidade e apenas 1 indivíduo (5%) do grupo LEDv/PC apresentou ainda dor leve. Em relação ao grau de mudança de cor, os grupos se comportaram de formas diferentes ao longo do tempo (p<0,0001). O E observado para o grupo LEDv/PC ficou acima do observado para o grupo LEDv em todos os momentos avaliados. Para o grupo LEDv/PC, o E manteve-se constante entre 24h após a primeira sessão e o início da segunda, com incremento no E após 24h da segunda sessão, mantendo-se constante até 6 meses, com pequeno decrescimento após 12 meses. O grupo LEDv não apresentou ganho significativo no clareamento (E) entre a primeira e segunda sessão, com ligeiro aumento após 1 mês da segunda sessão, seguido por decaimento após 6 meses e novo crescimento após 12 meses. O protocolo com LEDv/PC foi significativamente mais eficaz em relação ao efeito clareador, ao longo dos momentos avaliados, em relação ao grupo LEDv sem gel. Ambos os protocolos de clareamento apresentaram baixos níveis de sensibilidade nos intervalos de tempo estudados, com o grupo LEDv/PC apresentando maior nível de sensibilidade.
Title in English
Dental bleaching using violet LED associated or not with 37% carbamide peroxide: a randomized double-blinded clinical study
Keywords in English
Dental Esthetics
Dentin sensitivity
Tooth bleaching
Violet LED
Abstract in English
This study aimed to evaluate the effectiveness of in-office dental bleaching using violet LED associated or not with 37% carbamide peroxide. The response variables considered were the degree of change and color stability over 12 months and dental sensitivity over 1 month. An interventional randomized double-blinded clinical study for two in-office bleaching protocols was carried out using a violet LED system associated or not with 37% carbamide peroxide (PC). Forty participants, according to the inclusion and exclusion criteria, were randomly divided into 2 groups (n=20) following the bleaching protocol which was conducted in two sessions, 7 days apart: vLED - Violet LED (Bright Max Whitening®, MMOptics) without gel; vLED/CP - 37% carbamide peroxide (PowerBleaching Office®, BM4) photocatalized with violet LED. In the vLED group, the bleaching session was carried out by 2 consecutive 25' irradiation cycles (10 x 2' LED + 30 interval) with a 5-minute interval between cycles. In the vLED/CP group, the gel was applied 5 times in the bleaching session and photocatalyzed 3 times for 2 with 30 intervals (730 per gel application), reaching 3730 per session. Dental sensitivity was evaluated using a visual analogue scale (VAS) and the effectiveness of bleaching as to the function of the degree of change and color stability (E), using a spectrophotometer. Data were tabulated and submitted to statistical tests with p<0.05. The dental sensitivity analysis (VAS) showed that some individuals from both groups had mild pain (1VAS<4) in the various periods studied, and such data was more prevalent in the vLED/CP group than in the vLED group. Seven days after the 2nd session, only 1 individual (5%) in each group still had mild pain. Thirty days after the 2nd session, no individual in the vLED group showed sensitivity and only 1 individual (5%) from the vLED/CP group still had mild pain. Regarding the degree of color change, the groups behaved differently over time (p<0.0001). The E observed for the vLED/CP group was above the one observed for the vLED group at all moments. Regarding the vLED/CP group, the E remained constant, between 24h after the first session and the beginning of the second, with an increase in E after 24h of the second session, remaining constant until 6 months, with a small decrease after 12 months. The vLED/CP protocol was significantly more effective concerning the bleaching effect over the evaluated moments compared to the vLED group without gel. Both bleaching protocols showed low levels of sensitivity in the time intervals, and the vLED/CP group showed a higher level of sensitivity.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
There are withheld file due to requirements (data publishing, patents or rights).
Release Date
2024-09-01
Publishing Date
2021-10-22
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.