Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.25.2022.tde-18112022-172355
Document
Auteur
Nom complet
Thalita Tayná Henrique Dourado
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Bauru, 2022
Directeur
Jury
Duarte, Marco Antonio Hungaro (Président)
Silva, Guilherme Ferreira da
Tanomaru Filho, Mario
Vivan, Rodrigo Ricci
Titre en portugais
Avaliação do transporte apical, centralização, desgaste de dentina e volume final entre os sistemas mecanizados Genius Proflex, Trunatomy e Zenflex
Mots-clés en portugais
Habilidade de centralização
Micro-CT
Transporte apical
Resumé en portugais
O objetivo desse estudo foi avaliar o desgaste, centralização, transporte e volume de dentina remanescente após a instrumentação de três tipos de sistemas mecanizados no preparo de canais mesiais de molares inferiores. Quarenta e cinco molares inferiores com canais mesiais separados foram divididos em 3 grupos (n=15) de acordo com os sistemas: Genius ProFlex; ZenFlex; Truanatomy. Durante a instrumentação, 20 mL de hipoclorito de sódio foram utilizados e após, realizada irrigação com 2 mL de EDTA 17% por 3 minutos, e irrigação final com 5mL de soro fisiológico. Os escaneamentos das amostras por micro-CT foram realizados antes e após a instrumentação do canal mesiovestibular e mesiolingual para comparação de áreas tocadas e não tocadas. Os resultados foram analisados através do teste ANOVA seguido de Tukey (=0.05). Em relação ao transporte, não houve diferenças significativas entre os instrumentos em nenhum nível em ambos os canais (p>0,05). Na centralização, apenas ZenFlex obteve diferenças significativas comparado a TruNatomy no canal mesiolingual a nível de 3mm apical (p<0,05). Para alteração volumétrica, somente Genius ProFlex apresentou no canal mesiovestibular uma menor porcentagem de alteração quando comparado aos outros sistemas (p<0,05). O desgaste de dentina somente foi significativo no terço cervical do canal mesiovestibular, obtendo maior valor para parede distal com os sistemas TruNatomy e Genius ProFlex quando comparado ao ZenFlex (p<0,05). Os três sistemas de níquel-titânio proporcionaram um preparo seguro, sendo Genius ProFlex o sistema mais conservador.
Titre en anglais
Assessment of apical transport, centralization, dentin wear and volume increase proportionned by Genius Proflex, Trunatomy and ZenFlex mechanized systems
Mots-clés en anglais
Apical transportation
Centring ability
Micro-CT
Resumé en anglais
The aim of this study was to evaluate the wear, centering, transport and volume of remaining dentin after instrumentation of three types of mechanized systems in the preparation of mesial canals of mandibular molars. Forty-five lower molars with separate mesial canals were divided into 3 groups (n=15) according to the systems: Genius ProFlex; ZenFlex; Truanatomy. During instrumentation, 20 mL of sodium hypochlorite were used and afterwards, irrigation was performed with 2 mL of 17% EDTA for 3 minutes, and final irrigation with 5 mL of saline solution. Micro-CT scans of samples were performed before and after instrumentation of the mesiobuccal and mesiolingual canal to compare touched and untouched areas. The results were analyzed using the ANOVA test followed by Tukey (=0.05). Regarding transport, there were no significant differences between the instruments at any level in both channels (p>0.05). In centering, only ZenFlex obtained significant differences compared to TruNatomy in the mesiolingual canal at the apical 3mm level (p<0.05). For volumetric alteration, only Genius ProFlex presented a lower percentage of alteration in the mesiobuccal canal when compared to the other systems (p<0.05). Dentin wear was only significant in the cervical third of the mesiobuccal canal, obtaining a higher value for the distal wall with the TruNatomy and Genius ProFlex systems when compared to ZenFlex (p<0.05). The three nickel-titanium systems provided a safe preparation, with Genius ProFlex being the most conservative system.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Il ya retenu fichier en raison d'exigences (publication de données, des brevets ou droits).
Date de Libération
2024-09-14
Date de Publication
2022-11-21
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.