• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.25.2022.tde-18112022-172355
Documento
Autor
Nome completo
Thalita Tayná Henrique Dourado
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Bauru, 2022
Orientador
Banca examinadora
Duarte, Marco Antonio Hungaro (Presidente)
Silva, Guilherme Ferreira da
Tanomaru Filho, Mario
Vivan, Rodrigo Ricci
Título em português
Avaliação do transporte apical, centralização, desgaste de dentina e volume final entre os sistemas mecanizados Genius Proflex, Trunatomy e Zenflex
Palavras-chave em português
Habilidade de centralização
Micro-CT
Transporte apical
Resumo em português
O objetivo desse estudo foi avaliar o desgaste, centralização, transporte e volume de dentina remanescente após a instrumentação de três tipos de sistemas mecanizados no preparo de canais mesiais de molares inferiores. Quarenta e cinco molares inferiores com canais mesiais separados foram divididos em 3 grupos (n=15) de acordo com os sistemas: Genius ProFlex; ZenFlex; Truanatomy. Durante a instrumentação, 20 mL de hipoclorito de sódio foram utilizados e após, realizada irrigação com 2 mL de EDTA 17% por 3 minutos, e irrigação final com 5mL de soro fisiológico. Os escaneamentos das amostras por micro-CT foram realizados antes e após a instrumentação do canal mesiovestibular e mesiolingual para comparação de áreas tocadas e não tocadas. Os resultados foram analisados através do teste ANOVA seguido de Tukey (=0.05). Em relação ao transporte, não houve diferenças significativas entre os instrumentos em nenhum nível em ambos os canais (p>0,05). Na centralização, apenas ZenFlex obteve diferenças significativas comparado a TruNatomy no canal mesiolingual a nível de 3mm apical (p<0,05). Para alteração volumétrica, somente Genius ProFlex apresentou no canal mesiovestibular uma menor porcentagem de alteração quando comparado aos outros sistemas (p<0,05). O desgaste de dentina somente foi significativo no terço cervical do canal mesiovestibular, obtendo maior valor para parede distal com os sistemas TruNatomy e Genius ProFlex quando comparado ao ZenFlex (p<0,05). Os três sistemas de níquel-titânio proporcionaram um preparo seguro, sendo Genius ProFlex o sistema mais conservador.
Título em inglês
Assessment of apical transport, centralization, dentin wear and volume increase proportionned by Genius Proflex, Trunatomy and ZenFlex mechanized systems
Palavras-chave em inglês
Apical transportation
Centring ability
Micro-CT
Resumo em inglês
The aim of this study was to evaluate the wear, centering, transport and volume of remaining dentin after instrumentation of three types of mechanized systems in the preparation of mesial canals of mandibular molars. Forty-five lower molars with separate mesial canals were divided into 3 groups (n=15) according to the systems: Genius ProFlex; ZenFlex; Truanatomy. During instrumentation, 20 mL of sodium hypochlorite were used and afterwards, irrigation was performed with 2 mL of 17% EDTA for 3 minutes, and final irrigation with 5 mL of saline solution. Micro-CT scans of samples were performed before and after instrumentation of the mesiobuccal and mesiolingual canal to compare touched and untouched areas. The results were analyzed using the ANOVA test followed by Tukey (=0.05). Regarding transport, there were no significant differences between the instruments at any level in both channels (p>0.05). In centering, only ZenFlex obtained significant differences compared to TruNatomy in the mesiolingual canal at the apical 3mm level (p<0.05). For volumetric alteration, only Genius ProFlex presented a lower percentage of alteration in the mesiobuccal canal when compared to the other systems (p<0.05). Dentin wear was only significant in the cervical third of the mesiobuccal canal, obtaining a higher value for the distal wall with the TruNatomy and Genius ProFlex systems when compared to ZenFlex (p<0.05). The three nickel-titanium systems provided a safe preparation, with Genius ProFlex being the most conservative system.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Há arquivos retidos devido a solicitação (publicação de dados, patentes ou diretos autorais).
Data de Liberação
2024-09-14
Data de Publicação
2022-11-21
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.