• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.25.2020.tde-05102021-113227
Documento
Autor
Nombre completo
Thereza Cristina Lira Pacheco
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2020
Director
Tribunal
Oliveira, Pedro Cesar Garcia de (Presidente)
Cunha, Carolina Ortigosa
Falavinha, Lucimar
Lopes, José Fernando Scarelli
Título en portugués
Efeito de soluções higienizadoras na retenção de overdentures  com sistema Bola Mini
Palabras clave en portugués
Clorexidina
Desinfecção
Encaixe de Precisão de Dentadura
Hipoclorito de sódio
Prótese Total
Resumen en portugués
A utilização de meios químicos auxiliares para a limpeza de próteses totais tem demonstrado resultados satisfatórios na prevenção e tratamento de patologias orais. Entretanto, o uso de soluções higienizadoras podem provocar deterioração da base da prótese e pigmentação. Apesar de já se ter uma literatura consolidada a respeito da desinfecção em próteses totais convencionais, pouco se conhece sobre os efeitos destas soluções na longevidade dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring Bola Mini (Neodent®). Foram confeccionados 40 espécimes contendo um par de attachments o´ring, simulando uma overdenture, e apenas 01 contendo dois pilares o´ring. Eles foram separados em cinco grupos (n=8), um grupo ficou livre de imersões e serviu como parâmetro de comparação, os outros foram submetidos ao equivalente a três meses de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (INSTRON e3000), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de 90 dias. Os resultados foram avaliados estatisticamente através da análise variância de ANOVA e do teste de Tukey (p0.05). Imersões em soluções higienizadoras associadas a ciclos de inserção e remoção afetaram de maneira significativa a capacidade de retenção dos sistemas do sistema Bola Mini (p=0.000), porém não houve diferença estatisticamente significativas entre o tipo de solução utilizada (p=0.605). Os valores médios (N) encontrados após a ciclagem mecânica foram respectivamente: Água 24,831 ± 3,7; Clorexidina 20,274 ± 6,7; Hipoclorito: 20,174 ± 3,8 e Corega® Tabs: 21,345 ± 2,5. Assim, pôde-se concluir que soluções higienizadoras afetaram de maneira significativa a capacidade de retenção dos o´rings após o período equivalente a três meses de imersão.
Título en inglés
Palabras clave en inglés
Chlorhexidine
Denture Complete
Denture Precision Attachment
Disinfection
Sodium Hypochlorite
Resumen en inglés
The use of auxiliary chemical methods for cleaning total dentures has shown satisfactory results in the prevention and treatment of oral pathologies. However, the use of denture cleansing solutions may cause deterioration of the prosthesis base and pigmentation. Despite having a well-established literature and respecting disinfection in full dentures, little is known about the effects of these solutions on the longevity of overdenture retention systems. In this mode, this study will seek to assess immersions in 2% chlorhexidine, 1% sodium hypochlorite, Corega® Tabs and water (control) may prevent retention loss in Mini Ball (Neodent®) attachments. Forty specimens containing one attachment were simulated, simulating an overdenture and only 01 containing two pillars. They were separated into five groups (n = 8), one group was free of immersion and served as a comparison parameter, the others were subjected to three months of immersion. Afterwards, removal resistance tests were performed on a mechanical testing machine (INSTRON e3000), before and after a 270-cycle cycling, equivalent to the removal and insertion of prostheses three times daily for a period of 90 days. Results were statistically evaluated by analysis of variance of ANOVA and Tukey test (p0.05). Immersions in cleansers solutions associated with insertion cycles and significantly affected changes in the retention capacity of Bola Mini system systems (p = 0.000), but there was no statistically significant difference between the type of solution used (p = 0.605). The mean values (N) found after a mechanical cycling were respectively: Water - 24,831 ± 3,7; Chlorhexidine - 20,274 ± 6.7; Hypochlorite: 20,174 ± 3,8 and Corega® Tabs: 21,345 ± 2,5. Thus, it was concluded that denture cleansing solutions affect the retention capacity of the rings after a period of three months of immersion.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2021-10-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.