Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.25.2011.tde-27072011-100821
Document
Auteur
Nom complet
Raquel Sampaio Agostinho Pesse
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Bauru, 2011
Directeur
Jury
Alvarenga, Katia de Freitas (Président)
Lopes, Andréa Cintra
Saes, Sandra de Oliveira
Titre en portugais
Potencial evocado auditivo de longa latência para o estímulo de fala apresentado com diferentes transdutores em crianças normais
Mots-clés en portugais
Criança
Potenciais evocados auditivos
Transdutores
Resumé en portugais
No processo de indicação e adaptação do Aparelho de Amplificação Sonora Individual, as informações obtidas por meio dos Potenciais Evocados Auditivos de Longa Latência, geralmente pesquisado em campo livre, têm sido utilizadas para a avaliação dos benefícios e limitações dos dispositivos eletrônicos aplicados à surdez. O objetivo foi o de analisar de forma comparativa, a influência do transdutor no registro dos componentes P1, N1 e P2 eliciados por estímulo de fala, quanto à latência e amplitude, em crianças ouvintes. A casuística foi formada por 30 crianças ouvintes de quatro a 12 anos de idade de ambos os sexos. Os potenciais evocados auditivos de longa latência foram pesquisados por meio dos transdutores, fone de inserção e caixa acústica, eliciados por estímulo de fala /da/ apresentado com 526ms de intervalo interestímulos, na intensidade de 70dBNA e taxa de apresentação de 1,9 estímulos por segundo. A estimulação foi definida aleatoriamente, ora na orelha direita ora na esquerda, assim como a ordem do tipo do transdutor, iniciando ora pelo fone de inserção ora pela caixa acústica. Foram analisados os componentes P1, N1 e P2 quando presentes, quanto à latência e amplitude. Para verificar a reprodutibilidade dos registros, realizou-se uma análise de concordância entre a pesquisadora e um juiz, que mostrou um nível de concordância forte. Não houve diferença estatisticamente significante ao comparar os valores de latência e amplitude dos componentes P1, N1 e P2, para cada tipo de transdutor, considerando o sexo e orelha, assim como entre os tipos de transdutores utilizados ao comparar os valores de latências dos componentes do potencial evocado auditivo de longa latência. Entretanto, houve diferença estatisticamente significante na amplitude dos componentes P1 e N1 obtidos com os transdutores caixa acústica e fone de inserção, com maior amplitude para o transdutor caixa acústica. Os valores de latência dos componentes P1, N1 e P2 e amplitude de P2 obtidos com fone de inserção podem ser utilizados como referência para análise do registro obtido com o transdutor caixa acústica.
Titre en anglais
Late auditory evoked potentials to speech stimuli presented with different transducers in normal children
Mots-clés en anglais
Auditory evoked potentials
Child
Transducers
Resumé en anglais
In the process of indication and fitting of Hearing Aids, the data obtained through Long Latency Auditory Evoked Potentials, generally researched in free field, have been utilized to assess the benefits and limitations of electronic devices applied to deafness. The goal was to analyze, in a comparative manner, the influence of the transducer on the recordings of components P1, N1 and P2, elicited through speech stimulus, as to the latency and amplitude, in hearing children. The sample was comprised of 30 hearing children aged 4-12 yrs, of both genders. The long latency auditory evoked potentials were researched by means of transducers, insertion phone and speakers, elicited through speech stimulus /da/ presented with 526ms of interstimuli interval, in the intensity of 70dBNA and presentation rate of 1.9 stimuli per second. The stimulation was randomly defined, sometimes on the right ear, sometimes on the left one, as well as the order of the type of transducer, beginning, sometimes, with the insertion phone, and sometimes, with the speaker. Whenever present, components P1, N1 and P2 were analyzed as to latency and amplitude. In order to verify the reproducibility of the recordings, an agreement analysis was carried out between the researcher and a referee, showing a strong agreement level. No statistically significant difference was seen when comparing the latency and amplitude values of components P1, N1 and P2, for each type of transducer, taking into account the gender and ear, as well as among the types of transducers utilized when comparing the latency values of the components of long latency auditory evoked potential. Nevertheless, there was a statistically significant difference in the amplitude of components P1 and N1, obtained with the speaker and insertion phone transducers, with greater amplitude for the speaker transducer. The latency values of components P1, N1 and P2 and amplitude of P2 obtained with the insertion phone may be utilized as a reference for the analysis of the recording obtained with the speaker transducer.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2011-07-27
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.