Disertación de Maestría
DOI
https://doi.org/10.11606/D.25.2023.tde-18052023-144643
Documento
Autor
Nombre completo
Anilton Pinheiro da Silva
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2023
Director
Tribunal
Alvarenga, Katia de Freitas (Presidente)
Balen, Sheila Andreoli
Jacob, Lilian Cássia Bornia
Valenti, Vitor Engracia
Título en portugués
Desenvolvimento de um protótipo de equipamento para auxiliar na identificação das crianças com risco de perda auditiva em seu primeiro ano de vida
Palabras clave en portugués
Desenvolvimento de dispositivo
Risco de perda auditiva
Variabilidade da frequência cardíaca
Resumen en portugués
O objetivo deste trabalho foi de desenvolver um protótipo de equipamento (dispositivo) que pode auxiliar na identificação das crianças com risco de perda auditiva em seu primeiro ano de vida, na atenção primária e para ser utilizado durante as consultas de puericultura nas unidades básicas de saúde. O estudo foi dividido em duas etapas: a primeira consistiu no detalhamento do desenvolvimento do dispositivo e a segunda na calibração (aferição) em relação à emissão acústica e comparação da variabilidade da frequência cardíaca com equipamento de referência no mercado. Na elaboração do dispositivo foi utilizado o modelo do processo de desenvolvimento de produto (PDP) que tem como processo a fase de pré-desenvolvimento (planejamento) e fases do desenvolvimento, como a descrição do projeto detalhado. Na etapa dois houve a calibração do dispositivo em relação à emissão acústica, comparação da variabilidade da frequência cardíaca com equipamento referência no mercado - a cinta de captação de frequência cardíaca Polar RS800CX® (Polar Electro, Finlândia) - por meio da análise estatística e confiabilidade dos dados. A calibração foi feita pela empresa especializada manutenção de produtos eletromédicos audiológicos, ACÚSTICA ORLANDI, situada na cidade de Bauru. Foram selecionados 20 indivíduos adultos, sem perda auditiva, entre 18 e 40 anos. O procedimento de captação do batimento cardíaco foi simultâneo, foram testados os dois equipamentos, o dispositivo e o polar RS800CX, em um mesmo indivíduo, sendo o sensor de pulso (do dispositivo) de sinal cardíaco preso no dedo de uma das mãos (exceto polegar), sendo recomendado o dedo indicador [MANUAL DO FABRICANTE Oxímetro de pulsação de dedo modelo onyx 9500] do sujeito e a cinta fixada no peito, ficando o relógio monitor em posse do aplicador da coleta. Os dados gerados foram analisados pelo software estatístico Statistical Package for Social Sciences® (SPSS) versão 17.0, foram empregados o teste de Shapiro-Wilk, o teste t pareado, o teste não paramétrico de Wilcoxon, o teste de Bland-Altman, teste de correlação de Pearson e Spearman. Os resultados dos testes estatísticos mostraram, por meio do teste paramétrico t pareado para os índices RMSSD e SD1 nas intensidades de 50, 60 e 70 dBNA e o Willcoxon para o silêncio e 80 dBNA, a compatibilidade nas medições feitas pelos dois dispositivos, ressalta-se que este resultado foi confirmado quando se analisou a concordância entre o dispositivo e o POLAR RS800CX na medição dos índices, por meio do teste Bland-Altman. A princípio os índices estudados não foram influenciados pela presença do ruído branco nas diferentes intensidades, porém não é possível generalizar este achado para a população infantil, ou seja, crianças no primeiro ano de vida, pois essas possuem um sistema nervoso autônomo em processo de maturação, o que reflete na variabilidade da frequência cardíaca (VFC). Entende-se que o dispositivo poderá auxiliar em novas pesquisas, com o intuito de confirmar ou não a existência da associação entre a VFC e a acuidade auditiva em crianças no primeiro ano e vida.
Título en inglés
Development of a prototype of equipment to assist in the identification of children at risk of hearing loss in their first year of life
Palabras clave en inglés
Device development
Heart rate variability
Risk of hearing loss
Resumen en inglés
This work aimed at developing a prototype of equipment (device) that may assist in the identification of children at risk of hearing loss in their first year of life, in primary care and to be used during childcare consultations in basic health units. The study was divided into two stages: the first consisted in detailing the development of the device, and the second in the calibration (measurement) in relation to the acoustic emission and comparison of heart rate variability with reference equipment on the market. In the elaboration of the device, the product development process (PDP) model which has as a process the pre-development phase (planning) and development phases, such as the detailed design description, was used; the second consisted in calibrating the device in relation to the acoustic emission, comparison of heart rate variability with equipment reference on the market - the heart rate sensor belt Polar RS800CX® (Polar Electro, Finland) - through statistical analysis and data reliability. The calibration was carried out by a company specialized in the maintenance of audiological electromedical products, ACÚSTICA ORLANDI, located in the city of Bauru. Twenty adult individuals with no hearing loss, aged 18-40 years, were selected. The heart rate capturing procedure was simultaneous, and the two equipments, the device and the polar RS800CX, were tested on the same subject, with the pulse sensor (of the device) of the heart signal attached to the finger of one hand (except the thumb), the index finger being recommended [MANUFACTURER´s MANUAL - Finger pulse oximeter model onyx 9500] and the strap attached to their chest, the monitor watch being in the possession of the collector. The data generated were analyzed using the Statistical Package for Social Sciences® (SPSS) version 17.0 statistical software; the Shapiro-Wilk test, paired t-test, Wilcoxon non-parametric test, Bland-Altman test, Pearson and Spearman correlation test were employed. The results of the statistical tests showed, through the paired parametric t test for the RMSSD and SD1 indices at intensities of 50, 60, and 70 dBHL and the Willcoxon test for silence and 80 dBHL, the compatibility in the measurements made by the two devices, it is noteworthy that this result was confirmed when the agreement between the device and the POLAR RS800CX was analyzed in the measurement of the indices, through the Bland-Altman test. At first, the indices studied were not influenced by the presence of white noise at different intensities, but it is not possible to generalize this finding to the infant population, i.e., children in their first year of life, because these have an autonomous nervous system in the process of maturation, which reflects in the heart rate variability (HRV). It is understood that the device may help in further research, in order to confirm or not the existence of the association between HRV and hearing acuity in children in their first year of life.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Ha ficheros retenidos debido al pedido (publicación de datos, patentes o derechos autorales).
Fecha de Liberación
2025-02-27
Fecha de Publicación
2023-05-22
 