• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.25.2003.tde-26042005-153905
Document
Author
Full name
Rudys Rodolfo De Jesus Tavarez
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2003
Supervisor
Committee
Bonachela, Wellington Cardoso (President)
Elias, Carlos Nelson
Pinto, Joao Henrique Nogueira
Porto, Vinícius Carvalho
Silva, Antonio Materson da
Title in Portuguese
Análise comparativa das interfaces de implantes de conexão externa e interna em restaurações unitárias cimentadas e parafusadas, por meio de ensaios de fadiga.
Keywords in Portuguese
ensaios de fadiga
implante unitário
prótese sobre implantes ósseointegrados
Abstract in Portuguese
O sucesso da restauração protética suportada por implantes osseointegrados e a saúde dos tecidos circundantes estão intimamente relacionadas à precisão e adaptação dos componentes, a estabilidade da interface implante / pilar, assim como à resistência desta interface quando é submetida a cargas durante a função mastigatória. A restauração unitária é biomecanicamente mais complicada quando se trata da substituição de elementos dentários nas áreas de pré-molares e molares, devido às forças oclusais serem maiores nestas áreas, podendo levar a elevados níveis de tensão. Dessa forma, o objetivo deste trabalho foi o de estudar as alterações na interface implante / pilar em sistemas de conexão externa e interna através das medidas da desadaptação, e a condição de torque e destorque dos parafusos de fixação quando submetidos a ensaios de fadiga. Cinqüenta corpos de provas divididos em cinco grupos foram estudados: Grupo I implante HE e pilar UCLA, com restauração cimentada; Grupo II implante de HI e pilar pré-fabricado, com restauração cimentada; Grupo III implante OI e pilar pré-fabricado, com restauração cimentada; Grupo IV implante de HE e pilar UCLA, com restauração parafusada; e Grupo V implante HE e pilar ceraone, com restauração cimentada. As dimensões das bases de assentamento dos implantes e pilares, e dos parafusos dos cinco grupos foram medidas. Os corpos de prova foram submetidos a ensaios de fadiga até 500.000 ciclos utilizando-se uma máquina de ensaio MTS 810. Testes de torque e destorque nos parafusos de fixação, e análise da desadaptação da interface implante / pilar antes e depois da aplicação das cargas foram realizados. Através da análise variância com nível de significância de 5% e do teste Tukey para comparações múltiplas, foi possível observar que: (1) houve diferenças no diâmetro da base de assentamento dos implantes e pilares entre – 0,03mm a 0,75mm; e no diâmetro do hexágono / octágono entre implantes e pilares entre 0,01 e 0,05mm, sendo que no grupo que utilizou hexágono interno não foram encontradas diferenças; (2) o comprimento dos parafusos variou entre 5,95mm e 8,83mm, o comprimento das roscas variou entre 4,52 e 5,72mm, enquanto que o diâmetro entre 1,79 e 1,97mm; (3) após o ensaio de fadiga, houve um aumento hexágono externo que utilizaram pilares UCLA e no grupo de octágono interno; sendo a menor desadaptação observada no grupo de hexágono externo que utilizou pilares Ceraone (3,81 ìm); (4) houve redução estatisticamente significante da condição de torque dos grupos estudados após o ensaio de fadiga. A menor redução foi encontrada no grupo de hexágono interno com 5,3 N.cm (17,67%); e a maior redução no grupo de hexágono externo que utilizou pilares UCLA parafusados com 20,5 N.cm (68,33%); (5) houve uma forte correlação entre a aplicação das cargas cíclicas e a diminuição da condição de torque; enquanto que nas demais variáveis não existiu esse tipo de correlação.
Abstract in English
The long term success of an implant supported restoration and the health of the surrounding tissues is closely related to prosthetic components accuracy and its fit to the fixture and abutment implants interface stability as well as its strength when subjected to masticatory loads. Under a biomechanical standpoint implant single restoration in premolar and molar areas is the most complex issue; since occlusal forces are higher in these areas, leading to high level of stress over these components. Thus, this study investigates the alterations under cyclic fatigue in implant / abutment interface, in intern and extern connection systems through measurements of components fit, in abutment screw torque and in detorque. Fifty samples constituted of implants / abutments / crowns were divided into five groups of ten as follows: Group I was comprised of External Hexagon Implants / abutments and crown cast directly on UCLA abutment; Group II was comprised of Internal Hexagon implants and prefabricated abutments with cemented restoration; Group III was comprised of Intern Octagonal Implants and prefabricated abutments with cemented restoration; Group IV was comprised of External Hexagonal implants and UCLA abutments with a crown cast subsequent attached to the implant; and Group V was comprised of External Hexagonal Implants and prepared ceraone abutments, with cemented restorations. Dimensions of implants, abutments bases and abutment screws were obtained. Analysis of implant/abutment interface was performed. The torque was set according manufactures instructions. All samples were subjected to 500.000 fatigue cycles in a MTS 810 Universal Machine. Detorque tests in abutment screws were performed after cyclic fatigue as well as analysis of implant/abutment interface. Statistical analysis showed that: (1) There were differences in the width of implant and abutment bases ranged between 0,03mm to 0,75mm; in the hexagonal width of implant and abutments ranged between 0,01 and 0,05mm, but in Group II, constituted of intern hexagon; (2) The abutment screw length ranged between 5,95mm and 8,83mm, as long as their diameter ranged between 1,79 and 1,97mm; (3)After cyclic fatigue, there were a significant increase in the misfit between implant and abutment of extern hexagon with UCLA abutment and in inter hexagon group; the smallest misfit was observed in the extern hexagon with ceraone abutment group (3,81 ìm); (4) There were a statistically significant reduction in torque load in all groups after cyclic fatigue. The least reduction was found in the intern hexagon with cemented restoration group 5,3N/cm (17,67%), and the most reduction was found in the screwed UCLA abutment group 20,5N/cm (68,33%); (5) There were a strong correlation between cyclic loading input and the decrease of torque, and no other correlation was found regarding the other variables.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2005-05-31
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.