• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.25.2007.tde-13062007-160803
Document
Author
Full name
Daniel Eduardo Bayardo-González
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2007
Supervisor
Committee
Bonfante, Gerson (President)
Correr Sobrinho, Lourenço
Oliveira, Pedro Cesar Garcia de
Title in Portuguese
Avaliação da resistência à fratura em coroas metalocerâmicas e ceramocerâmicas, utilizando infra-estruturas com e sem reforço
Keywords in Portuguese
cinta lingual
coroas ceramocerâmicas
coroas metalocerâmicas
desenho da infra-estrutura
poste proximal
resistência à fratura
Abstract in Portuguese
As restaurações metalocerâmicas apresentam relatos de sucesso clínico a longo prazo e as características de reforço (cinta lingual e poste proximal) das infra-estruturas metálicas parecem ser de grande importância para este sucesso. Estes reforços freqüentemente estão ausentes nas infraestruturas das restaurações ceramocerâmicas. O objetivo deste estudo foi testar a hipótese nula de que coroas confeccionadas com infra-estruturas cerâmicas com desenho com e sem reforço não resultam em valores de resistência à fratura diferentes de coroas com infra-estruturas metálicas confeccionadas com os mesmos desenhos. Para a realização deste trabalho foram fabricadas 40 coroas, dividas em quatro grupos (n=10): (1) coroas metalocerâmicas - infra-estrutura com reforço; (2) coroas metalocerâmicas - infra-estrutura sem reforço; (3) coroas ceramocerâmicas - infra-estrutura com reforço; e (4) coroas ceramocerâmicas - infra-estrutura sem reforço. Os corpos de prova foram cimentados com ionômero de vidro modificado por resina nos troquéis metálicos e submetidos à análise de resistência à fratura usando uma máquina de teste universal Kratos, a uma velocidade de 0,5 mm/min. Todos os corpos de prova foram mantidos sob pressão até a fratura. Os resultados de resistência à fratura (kgf) foram submetidos à análise de variância (ANOVA) a dois critérios e ao teste de Tukey. O nível de significância considerado em todas as análises foi de 5% (p<0,05). Os valores médios de resistência à fratura foram de 237,637 kgf para as coroas metalocerâmicas com infraestruturas com reforço, 171,738 kgf para as coroas metalocerâmicas com infraestruturas com reforço, 127,588 kgf para as coroas ceramocerâmicas com infra-estruturas com reforço e 93,914 kgf para as coroas ceramocerâmicas com infra-estruturas sem reforço, com diferença estatisticamente significante (p<0,05), entre os quatro grupos. As coroas metalocerâmicas com reforço (Grupo 1) apresentaram o maior valor de resistência à fratura e estatisticamente significante, entre todos os grupos. As coroas confeccionadas com infra-estruturas com reforço apresentaram maior resistência à fratura do que as confeccionadas sem reforço, tanto nas coroas metalocerâmicas como nas ceramocerâmicas.
Title in English
Fracture resistance of metal-ceramic and all-ceramic crowns made with and without reinforced coping design
Keywords in English
all-ceramic crowns
buttressing shoulder
coping design
fracture resistance
lingual collar
metal-ceramic crowns
Abstract in English
Metal-ceramic restorations present reports of long-term clinical success, and the characteristics of reinforcement coping (lingual collar and buttressing shoulder) seem to be of great importance for this success. These reinforcements are often absent in all-ceramic coping restorations. The aim of the current study was to evaluate and compare the in vitro fracture resistance of metal-ceramic and In-Ceram Alumina all-ceramic crowns, with and without reinforced coping design. Forty crowns were fabricated and divided into four groups (n=10): group 1, metal-ceramic crown with reinforced coping design; group 2, metal-ceramic crown without reinforced coping design; group 3, allceramic crown with reinforced coping design and group 4, all-ceramic crown with out reinforced coping design. The forty crowns were cemented on stainless steel dies and axially loaded in a universal testing machine until fracture occurred, and the maximum load (kgf) was recorded. Data were analyzed by one-way analysis of variance (ANOVA) and Tukey test (p<0.05) The results showed a statistical significant superiority (p<0.05) of the reinforcement coping groups (237.637 kgf for metalo-ceramic crowns and 127.588 kgf for all-ceramic crowns), regarding to non reinforcement coping groups (171.738 kgf for metalo ceramic crowns and 93.914 kgf for all-ceramic crowns). These founds denote that: (1) crowns made with reinforcement coping had presented greater fracture resistance than those confectioned without it and (2) metal-ceramic crowns had presented greater fracture resistance than all-ceramic crowns.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
DanielGonzalez.pdf (799.84 Kbytes)
Publishing Date
2007-06-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.