Master's Dissertation
DOI
https://doi.org/10.11606/D.25.1998.tde-05012005-113204
Document
Author
Full name
Stefania Carvalho Kano
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 1998
Supervisor
Committee
Bonfante, Gerson (President)
Brosco, Heli Benedito
Francischone, Carlos Eduardo
Title in Portuguese
Avaliação da Adaptação da Interface Intermediário/ Cilindro de Ouro e da Compatibilidade de Diferentes Sistemas de Implantes Odontológicos: Análise Inrta e Entre - Sistemas.
Keywords in Portuguese
implantes dentários
Abstract in Portuguese
A adaptação passiva entre prótese e intermediário é considerada um requisito básico para o sucesso do tratamento protético em implantes odontológicos, embora pouco se saiba do grau de adaptação apresentado pelos componentes usinados, antes mesmo de serem utilizados. As diferentes soluções protéticas aumentaram o número de sistemas de implantes chamados compatíveis, mas existe uma dificuldade em prever a resposta biológica de um implante frente a estresses constantes, recomendando-se, em qualquer sistema utilizado, uma adaptação passiva. O objetivo deste trabalho foi avaliar a adaptação na interface intermediário e cilindro de ouro utilizando-se componentes de um mesmo sistema de implantes e combinações de componentes de diferentes sistemas. Componentes de 6 sistemas de implantes compatíveis foram utilizados: 3I, Lifecore, Conexão, Implamed, Nobelbiocare e NAPIO. Após a adaptação dos mesmos, o aperto dos parafusos foi padronizado com o auxílio de um torquímetro eletrônico. Os resultados da análise intra-sistema, após leitura em microscópio, não foram estatisticamente significantes entre os sistemas em relação ao desajuste (desajuste médio de 7,85µm), por outro lado, o melhor ajuste foi encontrado para os sistemas Nobelbiocare (94.44%) e Implamed (90.27%) e o pior para os sistemas Lifecore (33.33%) e 3I (26,38%). Analisados os resultados da análise entre-sistemas, sugere-se que nem todas as combinações podem ser consideradas compatíveis.
Abstract in English
The absolutely precise fit between prosthesis framework and abutment is very important for the long-term success of the implant-prosthetic treatment, although little is known about the fit of the machined components. The different prosthetic solutions has increased the number of implant systems that claim to be “compatible" to all Branemark-like Systems, but due to the current impossibility to predict the biologic response of an implant under constant strain, it is highly recommended to achieve a passive fitting framework. The purpose of this investigation was to determine the fit and the compatibility within and between different implant systems components at the abutment/gold cylinder interface. Implants components from 3I, Lifecore, Conexão, Implamed, Nobelbiocare and NAPIO were evaluated. Assembly of the components were standardized by using an electronic torquing device. The within systems results for misfit were not different (mean=7,85µm), but the best fit was found for Nobelbiocare and Implamed components and the worst for Lifecore and 3I. The between-systems results suggest that compatibility can not be achieved with all combinations.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
StefaniaCarvalhoKano.pdf (796.73 Kbytes)
Publishing Date
2005-01-18
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.