Thèse de Doctorat
DOI
https://doi.org/10.11606/T.25.2009.tde-30062009-160911
Document
Auteur
Nom complet
Etiene de Andrade Munhoz
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Bauru, 2009
Directeur
Jury
Ferreira Júnior, Osny (Président)
Almeida, Ana Lúcia Pompéia Fraga de
Camarini, Edevaldo Tadeu
Carvalho, Paulo Sergio Perri de
Rezende, Maria Lucia Rubo de
 
Titre en portugais
Avaliação radiográfica, biomecânica e microscópica de enxerto ósseo xenogênico associado a implantes de titânio em mandíbula de coelhos
Mots-clés en portugais
Enxerto xenogênico
Implantes de titânio
Microscópio confocal
Resumé en portugais
O propósito deste trabalho foi avaliar a interação de matriz óssea bovina inorgânica, (Gen-ox®) como material de enxerto e implantes de titânio em mandíbula de coelhos. A amostra constituiu-se de 32 coelhos da raça Botucatu de aproximadamente 4kg. Os incisivos inferiores destes animais foram extraídos e foi realizada um defeito de aproximadamente 4mm de diâmetro. Um dos lados foi mantido apenas com coágulo (grupo controle) e o outro lado (grupo experimental) recebeu o enxerto do material proposto. Após 60 dias foram instalados implantes bilateralmente na região do defeito. Os animais foram eutanaziados imediatamente após a instalação dos implantes e após 1, 2 e 6 meses (n=6) para o grupo microscópico a após 2 e 6 meses para o grupo do teste biomecânico (n=4). A análise constituiu de medidas da distância da crista óssea alveolar à plataforma do implante, da densidade radiográfica em valores de pixel ma região do alvéolo, de teste biomecânico de torque de remoção e microscópico através de medidas de contato osso-implante (BIC) (em µm e %) e área de osso (em µm2 e %). Os resultados demonstraram que não houve diferenças significantes nem durante o tempo e nem entre os grupos na analise de distancia entre crista óssea alveolar e plataforma do implante. Na medida de densidade óssea, não houve variação significante ao longo do tempo, mas houve diferença estatisticamente significante entre os grupos, sendo maior no grupo experimental. Para o teste biomecânico também não houve variação significante do torque de remoção ao longo do tempo e nem houve diferença significante entre os grupos. Na análise de contato osso implante (BIC) não houve variação significante ao longo do tempo, mas houve diferença estatisticamente significante entre os grupos, sendo maior no grupo experimental e houve interação entre tempos e grupos. E com relação a medida de área de osso não houve diferenças significantes nem durante o tempo e nem entre os grupos controle e experimental nos períodos analisados. Os resultados sugerem que o material foi bem aceito na região e teve comportamento semelhante ao coágulo em contato com a superfície do implante.
 
Titre en anglais
Radiographic, biomechanical and microscopic evaluation of xenogenic bone graft associated to titanium implants in rabbits mandible
Mots-clés en anglais
Confocal microscope
Titanium implants
Xenogenic graft
Resumé en anglais
The aim of this study was to evaluate the interaction of an inorganic bovine bone matrix (Gen-ox®) as bone graft and titanium implants in rabbits mandible. Thirty-two Botucatu rabbits weighting about 4kg were used on this experiment. The mandible incisives were extracted and a defect of 4 mm of diameter was performed. One socket and defect was filled with experimental material. The opposite site was left to heal naturally and served as control. After 60 days, the implants were installed on the defect region. The animals were killed immediately after the implant installation and after 1, 2 and 6 months. Vertical bone height, bone density, biomechanical test, bone implant contact (BIC) and bone area near to implant threads were evaluated. The results showed that there was no significant differences on the distance between the alveolar bone crest to the implant platform (vertical bone height) along the time, neither between groups. On the bone density (pixel value) there was no significant difference along the time, but there was significant difference between groups, being the experimental group higher. For the biomechanical test there was no significant difference along the time, neither between groups. There was no significant differences on the bone implant contact (BIC) measures along the time, but there was significant difference between groups, being the experimental groups higher and there was interaction between time and groups. On bone area evaluation, there was no significant difference along the time, neither between the groups during the analyzed time. The graft behavior observed by the authors was similar to that of the control group, suggesting high acceptance of the material as graft option associated to titanium implants.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-07-02
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs.
CeTI-SC/STI
© 2001-2024. Bibliothèque Numérique de Thèses et Mémoires de l'USP.