• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2023.tde-19062023-125510
Documento
Autor
Nombre completo
Letícia Vilela Santos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2023
Director
Tribunal
Melani, Rodolfo Francisco Haltenhoff (Presidente)
Baccarin, Leandro Stocco
Beaini, Thiago Leite
Mazzilli, Luiz Eugênio Nigro
Título en portugués
Avaliação da posição anterior do globo ocular na face em tomografias com finalidade de reconstrução facial forense
Palabras clave en portugués
Globo Ocular
Odontologia Forense
Órbita
Reconstrução Facial Forense
Resumen en portugués
A reconstrução facial forense (RFF) busca reproduzir a imagem da face atribuída ao indivíduo, contribuindo para uma possível identificação quando outros métodos não podem ser aplicados. Para que a RFF se assemelhe às características do indivíduo, os anexos faciais como a orelha, olhos, nariz e boca, devem ser precisos em relação ao tamanho, posição e forma. Os olhos são essenciais na reconstrução de uma face passível de ser reconhecida porque que estão, expressivamente, posicionados no centro da face. No entanto, são poucos os estudos que estabelecem a posição do globo ocular e ainda não há parâmetros para essa característica em brasileiros. O objetivo deste trabalho foi estabelecer parâmetros da localização dos pontos pupilar (p), endocântio (en) e exocântio (ex) para posicionamento do globo ocular na população brasileira com finalidade de RFF. A pesquisa utilizou 69 tomografias computadorizadas de feixe cônico (TCFC), analisadas por meio do software Horos®. Primeiramente, o crânio foi posicionado no plano de Frankfurt, depois foram localizados os pontos p, en, ex, supraorbital médio (mso), infraorbital médio (mio), orbital médial (mo) e o ectocântio (ec). Foram mensuradas as medidas entre os pontos mso-mio, mo-ec, mio-en, mo-p, en-ex e en-p. Depois, foi mensurado o ângulo formado entre o en e o ex e a linha paralela ao plano de Frankfurt, e por último foi utilizado o método da tangente para medir a projeção da órbita. Foram realizadas análises descritivas e análise estatística por meio do software Jamovi. Pode-se estabelecer que o p tem localização estatisticamente correlacionada à largura da órbita (mo-ec) e à altura da órbita (mso-mio), sendo 58% da largura, a partir do ponto mo, e 46% da altura, a partir do ponto mio. Quanto à projeção do p em relação às margens da órbita, estima-se uma média de 3,74 mm. Estabelecida a posição do p, pode-se estimar a distância entre os pontos en-ex com aproximadamente 74% da largura da órbita, sendo que a distância do en-p representa 56% dessa grandeza estimada. Por fim, os pontos en-ex apresentam inclinação de 89º em relação à uma linha paralela à linha sagital do crânio. Houve pouca diferença estatisticamente significativa entre os sexos e aos lados direito e esquerdo, sendo que a diferença entre médias não justificou a separação do método por esses parâmetros.
Título en inglés
Anterior eyeball position evaluation in cone beam tomography with forensic facial reconstruction purposes
Palabras clave en inglés
Eyeball
Forensic Dentistry
Forensic facial reconstruction
Orbit
Resumen en inglés
Forensic facial reconstruction (FFR) reproduces a face image attributed to an individual, helping a possible identification when other methods are not available. Structures from the face such as the ears, eyes, nose, and mouth are essential to creating similarity to an individuals characteristics, therefore they must be precise in shape, position, and size. The eyes are an important face component in reconstructing a face passable of recognition once they are, expressively, in the center of the face. Few studies establish the eyeballs position and there are no parameters for these characteristics in Brazilians. This work aimed to establish parameters to locate the pupils point (p), endocanthion (en), and exocanthion (ex) to position the eyeball in the Brazilian population for FFR purposes. 69 cone beam tomographies (CBT) were used and analyzed through the Horos® software. First, the skull was positioned in Frankfurts plane and the points p, en, ex, medial orbit (mo), mid-infraorbital (mio), mid-supraorbital (mso), and ectoconchion (ec) were located. The distance between the points mso-mio, mo-ec, mio-en, mo-p, en-ex and en-p were measured. After the angle between en-ex and the parallel line to the sagittal line were measured and the tangent method was used to measure the orbit projection. The variables were described through descriptive analysis and the statistics were made through the Jamovi® software. The p points location is statistically correlated to the orbit width (mo-ec) and the orbit height (mso-mio), described as 58% of the width from the mo, and 46% of the height from the mio. The p projection is approximately 3,4 mm to the orbit margin. The distance between en-ex is estimated approximately as 74% of the orbit height, and the distance between en-p represents 56% of it. At last, the distance en-ex present an 89° inclination to the sagittal line. There were few statistical differences between the sexes and the right and left sides, and the mean difference did not justify the method separation through these parameters.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2023-07-25
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.