• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.23.2020.tde-24022021-124958
Document
Auteur
Nom complet
Caroline Hornink Rodrigues
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2020
Directeur
Jury
Caldeira, Celso Luiz (Président)
Coto, Neide Pena
Iglecias, Elaine Faga
Machado, Manoel Eduardo de Lima
Titre en portugais
Avaliação da precisão da técnica de cirurgia de acesso endodôntico guiada
Mots-clés en portugais
Acesso
Endodontia
Guia
Guia metálico
Resumé en portugais
O uso de guias cirúrgicos é recente na endodontia, e sua principal indicação é para os dentes que sofreram um grau elevado de calcificação, o que pode vir a dificultar a localização e o acesso dos canais radiculares. Este trabalho avaliou a influência das dimensões do guia metálico, do seu nicho e da broca, sobre a precisão da técnica, bem como a perda de massa em dente simulado para acessos em dois pontos de eleição distintos. Modelos impressos de dentes com raízes modificadas e guias cirúrgicos foram usados para simular acessos endodônticos guiados, com nichos para guias metálicos de 8 e 12mm de comprimento. As medidas referentes a desvios previstos e reais (pós-operatórios) foram aferidas por meio de perfilometria, e foram realizadas simulações de acesso em CAD (Computer Aided Design). Os valores médios e medianos de tolerância total e de tolerância entre nicho e guia metálico, assim como dos desvios previstos e reais, foram maiores para os guias metálicos de 12mm do que para os guias metálicos de 8mm; porém, os valores de tolerância entre guia metálico e broca foram maiores para os guias metálicos de 8mm do que para os de 12mm Houve perda de 6,7% de massa inicial quando o acesso simulado foi realizado somente na face palatina e de 7,3% quando realizado em face palatina e borda incisal. Em 36,67% dos acessos guiados o desvio real foi maior do que o desvio previsto. O valor de tolerância entre nicho e guia metálico é capaz de influenciar o desvio da trajetória da broca em cirurgia de acesso guiada, assim como a comumente estudada tolerância entre guia metálico e broca. O acesso guiado realizado somente na face palatina preserva mais massa dental do que na face palatina e borda incisal.
Titre en anglais
Evaluation of accuracy of the guided endodontic access technique
Mots-clés en anglais
Access
Endodontics
Guide
Sleeve
Resumé en anglais
The use of surgical guides is recent in Endodontics and is mainly applied to cases of pulpal obliteration, that may impair the location and access of root canals. This research evaluated the influence of the dimensions of the sleeve, its niche and the drill in the accuracy of the technique, as well as dental mass loss for two different access points. Printed models of teeth with modified roots and surgical guides were used to simulate guided endodontic access, with sleeves of 8 and 12mm of length. Measurements of predicted deviations and real deviations (measured after the procedure) were accessed with profilometry, and simulations of access were made in CAD (Computer Aided Design). The mean and median values of total tolerance and tolerance between sleeve and niche, as well as of predicted and real deviation, were greater for the 12mm sleeves than for the 8mm sleeves; although the values of tolerance between sleeve and drill were greater for the 8mm sleeves than for the 12mm sleeves. In 36.67% of the guided accesses the real deviation was greater than the predicted deviation. The access through the buccal wall only represented a loss of 6,7% of the total tooth mass, while the access through the buccal wall and incisal edged resulted in loss of 7,3% of the total mass. The tolerance between niche and sleeve can influence the drill deviation in guided access as well as the commonly studied tolerance between sleeve and drill. The guided access executed on buccal wall only preserves more dental mass than the guided access executed on buccal wall and incisal edge.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2021-02-27
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.