• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2011.tde-20092011-171438
Documento
Autor
Nombre completo
Luiz Vicente de Moura Lopes
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2011
Director
Tribunal
Morea, Gladys Cristina Dominguez (Presidente)
Moresca, Ricardo Cesar
Tortamano, André
Título en portugués
Avaliação das distribuições de tensões, por meio da análise de elementos finitos, em uma hemi-maxila, durante a fase de retração anterior por deslizamento, na mecânica ortodôntica
Palabras clave en portugués
Ancoragem Ortodôntica
Método dos Elementos Finitos
Retração por Deslizamento
Resumen en portugués
O objetivo deste estudo foi analisar, por meio do método dos elementos finitos, como ocorreram as distribuições de tensões nos dentes, osso e aparelho ortodôntico, durante a fase de retração por deslizamento (150g), em um caso com extrações. Simularam-se duas posições do gancho (mesial e distal de canino), duas alturas do gancho (4 e 9mm) e duas alturas posteriores (gancho do tubo do molar e no miniimplante, a 9mm do arco). A amostra consistiu do corte axial da TCFC, de uma mulher de 17 anos de idade, com dentes bem nivelados. Foi desenvolvido um modelo 3D, da geometria da hemi-maxila direita e um modelo numérico, para obter os regimes de tensões e deformações gerados em um sistema de movimentação ortodôntica, por meio do software ANSYS® versão 12.0. Os sólidos dos braquetes e do fio ortodôntico foram incluídos a partir das dimensões fornecidas pelo fabricante. A montagem de todos os componentes foi feita por meio do SolidWorks 2009 SP4.1. A partir do cálculo das respostas do modelo, às cargas a que foi submetido, verificou-se que, os dentes que sofreram maiores concentrações de tensões foram os justapostos aos ganchos, sendo mais intensas as do gancho mesial, particularmente nos incisivos laterais. Embora, a solicitação de tensões no arco tenha sido semelhante em todos os modelos, na posição distal do gancho, houve maior concentração de tensões na extensão imediatamente distal. Os modelos com ganchos de 4mm, diferente aos de 9mm, apresentaram distribuições de tensões mais uniformes, causando menos estresse aos dentes e osso e semelhante ao arco. O modelo com vetor de força direcionado do gancho da mesial do canino ao miniimplante foi o único que mostrou variações, mostrando distribuições de forças mais elevadas na região anterior e posterior ao ser comparado com o vetor de força direcionado ao tubo do primeiro molar.
Título en inglés
Evaluation of the tensions distributions, using the finite element analysis, in an hemi-maxilla during a sliding anterior retraction , in an orthodontic mechanics
Palabras clave en inglés
Finite Element Analysis
Orthodontics Anchorage
Sliding Mechanics
Resumen en inglés
The aim of this study was to evaluate, by means of finite element analysis, the tensions distrubutions on the teeth, bone and orthodontic appliance, during en-masse retraction sliding mechanics (150g), in an extraction case. It was taken into account two hook positions (mesial and distal to the canine), two hook heights (4mm and 9mm) and two posterior heights ( the first molar tube and the mini-implant, located 9mm from the archwire). The sample of this study consisted of an axial cut realized in a cone beam computed tomography of a 17 years old woman with leveling teeh. It was developed a 3D computed model of a right hemi-maxilla and a computednumerical model capable of getting the systems tensions and deformations generated from an orthodontic moviment system, through a finite element software, ANSYS® 12.0. Observing manufactores specifications, brakets and archwire solids were included in this solid geometric model. The assembly of all componentes were made though the SolidWorks 2009 SP4.1 software. The loads model responses were calculated. The bigger concentration of tension were on the teeth located between the hook. The model with the mesial hook, suffered more intense tensions, mainly on lateral incisors. Although, the tensions request on the archwire were similars in all models, when the hook was located distaly, there were more intense tensions in its immediately distal extension. The 4mm hook models, compared with the 9mm, presented more uniform tensions distribution causing less stress to the teeth and bone and similar to the archwire. The only model that demonstrated variations, was the model with the vector force from the mesial hook and to the mini-implant. This model, demostrated higher tensions distributions on the anterior and posterior region if compared to the first molar tube vector force.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2011-10-05
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.