• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2012.tde-15012013-161407
Documento
Autor
Nombre completo
José Augusto Conde Neto
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2012
Director
Tribunal
Mori, Matsuyoshi (Presidente)
Salomão, Pedro Antonio Santoro
Veiga, Jose Antonio Lupi da
Título en portugués
Estudo sobre o comportamento biomecânico de implantes curtos com variação da espessura da cortical óssea por meio do método dos elementos finitos
Palabras clave en portugués
Dente pré-molar
Implante dentário
Mandíbula
Osso e ossos
Simulação por computador
Titânio
Resumen en portugués
Este estudo teve como objetivo analisar e comparar o comportamento biomecânico de um implante de comprimento curto com um implante de comprimento padrão, no que diz respeito às tensões ósseas ao redor do implante. Foi considerado como variável o aumento da espessura óssea cortical, em dois tipos: fino e espesso. Os modelos de elementos finitos em três dimensões (3D) foram criados a partir de uma secção de mandíbula de 20 mm, referente ao segundo pré-molar, com um implante endósseo único inserido dentro do osso esponjoso com cortical fina de 0,5 mm e cortical espessa de 2,0 mm. Uma carga oclusal vertical de 100 N e uma carga oblíqua de 40 N foram aplicadas. Os ossos cortical e esponjoso foram considerados isotrópicos e linearmente elásticos e o critério de avaliação foi o de tensões de von Mises. O implante curto utilizado foi de 4,1 mm de diâmetro por 6,0 mm de comprimento, e o implante padrão de 4,1 mm de diâmetro por 10,0 mm de comprimento (ambos da marca Straumann®). A prótese sobre o implante foi composta por um pilar sólido de 5,5 mm de altura e por uma coroa de segundo pré-molar. Conforme as simulações pelo MEF, pôde-se concluir que: 1) O aumento da espessura óssea favoreceu uma melhor distribuição das tensões, registrando valores mais baixos na região cervical cortical. 2) O modelo de implante curto na situação de cortical espessa apresentou melhores resultados biomecânicos comparado com o modelo de implante padrão na situação de cortical fina.
Título en inglés
Biomechanical behavior of short implants varying thickness of cortical bone by finite element method
Palabras clave en inglés
Bone Thickness
Crestal Bone
Endosseous Dental Implant
Finite Element Analysis
Mandible
Short Implant
Resumen en inglés
The aim of this monograph was to analyze and compare the biomechanical behavior of a short length implant against a standard length implant, regarding stress distribution on the bone around the implant. Bone cortical thickness of the ridge was considered as thin and thick. The 3D finite element models were created of a 20-mm second premolar section of the mandible with a single endosseous implant embedded in cancellous bone with thin cortical of 0.5 mm and with thick cortical of 2.0 mm. A vertical occlusal load of 100 N and an oblique load of 40 N were applied. The cortical and cancellous bone were considered to be isotropic and linearly elastic Von Mises stress criterion was used for analysis. The short implant used was of 4.1 mm of diameter and 6 mm in length, and the standard implant was of 4.1 mm of diameter and 10 mm in length (both Straumann ®). The prosthesis on the implant consisted of a solid abutment of 5.5 mm in height and a crown of second premolar. Conclusions: 1) Increasing bone thickness favored a better stress distribution, showing lower values in the cervical cortical bone. 2) Short implants with thin cortical situations showed better biomechanical results compared to standard implants with thick cortical situations.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-02-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.