• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.23.2008.tde-10072008-153726
Document
Author
Full name
Priscila Galzo Marafon
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2008
Supervisor
Committee
Mattos, Beatriz Silva Camara (President)
Noritomi, Pedro Yoshito
Saboya, Antonio Carlos Lorenz
Title in Portuguese
Estabilidade dimensional em prótese óculo-palpebral confeccionada por meio de modelo reverso obtido pelo sistema CAD/CAM
Keywords in Portuguese
Medidas lineares
Pontos antropométricos
Prótese facial
Protótipo
Sistema CAD/CAM
Abstract in Portuguese
A disponibilidade da tecnologia CAD/CAM na área biomédica suscitou o desenvolvimento deste trabalho, onde se avalia a estabilidade das dimensões faciais em prótese óculo-palpebral. Tomografias computadorizadas da face de 15 indivíduos voluntários, maiores de 25 anos de idade, não portadores de lesão congênita ou adquirida na região crânio-facial e de ambos os gêneros, foram reformatadas no sistema CAD, gerando imagens espelhadas de 30 modelos tridimensionais da região óculo-palpebral. Estes modelos foram processados no sistema CAM, empregando-se a sinterização seletiva a laser, dando origem a 30 protótipos de superfície. Paralelamente foram realizadas duas moldagens faciais em cada indivíduo, obtendo-se 15 pares de modelos em gesso da face, nos quais foram simuladas lesões óculo-palpebrais padronizadas nos lado direito e esquerdo. Os protótipos de superfície foram adaptados nos respectivos modelos em gesso, removidos e incluídos em mufla para obtenção da prótese óculo-palpebral em silicone. A definição de pontos antropométricos na área da prótese e na linha mediana da face possibilitou o estabelecimento de 31 medidas lineares empregadas para a avaliação da estabilidade das dimensões da prótese óculo-palpebral e de seu posicionamento na face. Fundamentando-se na análise comparativa das medidas observadas no lado da prótese e no lado contra-lateral íntegro que deu origem ao protótipo de superfície, conclui-se que a prótese óculo-palpebral não apresenta alteração de suas dimensões vertical, transversal e oblíqua. Não ocorre alteração na profundidade da prótese óculo-palpebral nos modelos da face, como também a prótese não sofre deslocamento espacial na face nos sentidos transversal e oblíquos. O conjunto das mensurações relativas ao lado da prótese óculo-palpebral não é estável em relação ao conjunto do lado contra-lateral que deu origem a esta prótese. A estabilidade dimensional da prótese óculo-palpebral e o seu posicionamento na face são compatíveis com a utilização em clínica do sistema CAD/CAM avaliado nesta pesquisa.
Title in English
Dimensional stability in orbital prosthesis produced by means of reverse prototype generated by CAD/CAM system
Keywords in English
Antropometric landmarks
CAD/CAM system
Linear mensurements
Orbital prosthesis
Prototype
Abstract in English
The CAD/CAM technology available in the biomedical area gave rise to the development of this study in order to evaluate the dimensional stability of orbital prosthesis. Face computerized tomography of 15 adults, men and women older than 25 years of age not bearing congenital or acquired craniofacial defect, were processed in CAD (computer-aided design) software to produce 30 reverse tridimensional models of the orbital region. These models were then processed in the CAM system (computer-aided manufacturing), by means of laser selective sintering, to generate surface prototypes of the orbital region. Two facial impressions of each subject provided 15 pairs of cast models and orbital defects were performed either in the right or left side of each stone model. The surface prototypes were adapted in the casts and then flasked to be processed in silicone. The demarcation of anthropometric landmarks within the prosthesis and in the face midline defined 31 linear measurements, used to evaluate the dimensional stability of the orbital prostheses and its location in the face. In conclusion, the comparative analyses of the measurements, observed in the prostheses and in the opposite sides that originated the surface prototypes, showed that silicone orbital prostheses presented similar vertical, transversal and oblique dimensions, as well as similar depth. There is no transverse or oblique displacement of the prostheses. Combined measurements in the prostheses' side are not stable regarding the opposite side. The dimensional stability of orbital prostheses suggests that the CAD/CAM system evaluated herein may be used with clinical purposes.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
PriscilaGalzoMarafon.pdf (814.09 Kbytes)
Publishing Date
2008-09-03
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.