• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.23.2020.tde-30072020-101923
Documento
Autor
Nombre completo
Gonzalo André Montesinos Parra
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2020
Director
Tribunal
Oliveira, Jefferson Xavier de (Presidente)
Dutra, Marcelo Eduardo Pereira
Freitas, Claudio Froes de
Santos, Karina Cecilia Panelli
Título en portugués
Análise da aplicação de filtros de realce de imagem no diagnóstico de alterações patológicas da cabeça da mandíbula em exames de ressonância magnética e tomografia computadorizada
Palabras clave en portugués
Articulação Temporomandibular
Processamento de Imagem
Ressonância Magnética
Tomografia Computadorizada Espiral
Resumen en portugués
Entre os principais exames de imagem para se avaliar a articulação temporomandibular (ATM) destaca-se a ressonância magnética (RM) e a tomografia computadorizada espiral (TC). Por meio destes exames pode-se observar estruturas ósseas e tecidos moles para detectar alterações patológicas na ATM. A RM e a TC podem apresentar certas limitações na resolução espacial e a variação de contraste das estruturas anatômicas da ATM, assim como também a presença de artefatos podem implicar em problemas na qualidade da imagem e uma análise imprecisa. Atualmente, na Radiologia, se utiliza diferentes tipos de filtros de realce oferecidos pelos softwares de imagem beneficiando o diagnóstico. Neste estudo avaliamos a utilização de dois tipos de filtros (filtro Sharpen 3x3 ou F1 e filtro Sharpen 5x5 ou F2) pertencentes ao software Osirix MD para a observação de três alterações patológicas na cabeça da mandíbula: aplainamento, erosão e osteófito. Foram analisadas 77 ATMs em RM e TC. A avaliação da repetibilidade e reprodutibilidade dos examinadores foi realizada através de GEE (Genelarized Estimating Equations), e a comparação entre os filtros e entre as técnicas foi realizada através do teste Qui-Quadrado. Os resultados mostraram que a aplicação dos filtros melhoraram a qualidade de imagem na RM (F2>F1>SF), mas na TC só a aplicação do F1 melhorou a qualidade da imagem (F1>SF>F2).
Título en inglés
Analysis of applications of enhancement filters for the diagnosis of condyle pathologies on magnetic resonance and spiral computed tomography imaging
Palabras clave en inglés
Image processing
Magnetic Resonance Imaging
Spiral Computed Tomography Imaging
Temporomandibular joint
Resumen en inglés
Among the most important image exams to evaluate the temporomandibular joint (TMJ); magnetic resonance imaging (MRI) and spiral computed tomography (CT) are highlighted. The use of these exams allows us to visualize bone structures and soft tissues for the detection of pathological disorders on TMJ. However, the MRI and CT images have some limitations concerning: the spatial solution, contrast variation and artifacts of the TMJ anatomical structures. Currently on the Radiology field, we are using different types of filters, which are offered by imaging software's helping to get an accurate diagnosis. In this study, we evaluated two types of filters: Sharpen 3x3 or F1 and Sharpen 5x5 or F2 (Osirix MD software) for detection of three condyle pathologies: flattening, erosion and osteophytes. Seventy-seven TMJ were analyzed on MRI and CT images. Intra and interobserver concordance were measured by using GEEs (generalized estimating equations), image comparison quality of all filtered images and the comparison between the two techniques were analyzed using the chi square test. The results showed that the use of enhancement filters improved the quality of MRI images (F2>F1>WF); however CT images had a better image quality only using the F1 (F1>SF>F2).
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-09-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.