• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.23.2013.tde-18102013-185639
Document
Auteur
Nom complet
Renata de Saldanha da Gama
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2013
Directeur
Jury
Costa, Claudio (Président)
Arita, Emiko Saito
Rosa, Véra Lúcia Mestre
Titre en portugais
Acurácia de medidas lineares em região posterior de mandíbulas obtidas por tomografia computadorizada de feixe cônico através de diferentes protocolos de aquisição
Mots-clés en portugais
Acurácia
Tomografia
Tomografia Computadorizada de Feixe Cônico
Resumé en portugais
A utilização da tomografia computadorizada de feixe cônico (TCFC) permite avaliar a altura e espessura do osso remanescente para a instalação de implantes. As mandíbulas atrésicas necessitam de maior grau de detalhamento para obtenção de medidas. A autora, no presente estudo, avaliou a influência do tamanho dos voxels (0,125mm e 0,25mm) nas medidas de altura e espessura em 10 mandíbulas desdentadas e atrésicas. Para determinação dos cortes tomográficos no estudo foram utilizados fios metáticos nas regiões posteriores. Após o exame as mandíbulas foram seccionadas e as medidas diretas de altura e espessura foram obtidas pelo uso de paquímetro digital. Os resultados pelo teste ICC demonstraram não haver diferenças estatisticamente significantes entre as medidas realizadas pelos dois examinadores com paquímetro e as tomografias. Concluiu-se que a TCFC é confiável para realização de medidas na mandíbula e que o tamanho do voxel não interferiu no planejamento cirúrgico.
Titre en anglais
Accuracy of linear measurements in posterior region of mandible obtained by cone beam computed tomography through different acquisition protocols
Mots-clés en anglais
Accuracy
Cone Beam CT
Tomography
Resumé en anglais
The use of cone beam computed tomography (CBCT) allows to evaluate the height and thickness of the remaining bone for implant placement. The atresic mandible requires higher level of detail for obtaining measurements. The author in the present study evaluates the influence of the voxel size (0.125 mm and 0.25 mm) in thickness and height measurements using 10 edentulous dry mandibles. For determination of the tomographic study were used metallic wires in the posterior regions. After examining, the mandibles were sectioned and direct measures of height and thickness were obtained through digital caliper. The results by ICC test showed no statistically significant differences between the measurements with caliper and tomograms made by two examiners. It was concluded that CBCT is trusted to carry out measurements in mandible and the voxel size did not affect the surgical planning.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-01-08
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.