• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.22.2011.tde-28112011-165347
Documento
Autor
Nombre completo
Ligia de Sousa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2011
Director
Tribunal
Nakano, Ana Marcia Spano (Presidente)
Gomes, Flávia Azevedo
Lopes, Maria Helena Baena de Moraes
Meirelles, Maria Cristina Cortez Carneiro
Shimo, Antonieta Keiko Kakuda
Título en portugués
Avaliação da eletroestimulação nervosa transcutânea para alívio da dor de contração uterina pós-parto durante a amamentação: ensaio clínico randomizado
Palabras clave en portugués
amamentação
Contração uterina
dor
Eletroestimulação Nervosa Transcutânea.
período pós-parto
Resumen en portugués
Durante a amamentação ocorre a liberação de ocitocina para a ejeção do leite, que desencadeia a contração uterina, associada a processo doloroso. A Eletroestimulação Nervosa Trânscutânea (TENS) é um recurso fisioterapêutico que tem como função o alívio da dor. O objetivo principal deste estudo foi avaliar a efetividade da TENS para alívio de dor de contração uterina durante a amamentação em multíparas após o parto vaginal. Como objetivo específico visou mensurar e caracterizar a dor de contração uterina e identificar queixas álgicas durante a amamentação. Trata-se de um estudo clínico controlado e randomizado, composto por 32 multíparas após o parto vaginal, durante a amamentação. O estudo foi desenvolvido dentro dos padrões éticos, sendo aprovado pelo Comitê de Ética em Pesquisa da Escola de Enfermagem de Ribeirão Preto - USP. O estudo foi realizado em uma maternidade no interior do estado de São Paulo. As participantes foram alocadas de maneira aleatória, no alojamento conjunto. As participantes foram divididas em dois grupos, o grupo experimental (GE) que recebeu a aplicação de TENS convencional e o grupo controle (GC). Para o GE os eletrodos da TENS convencional foram posicionados na região paravertebral (T10-L1 e S2- S4), programado para gerar frequência de 80Hz, duração de pulso de 100?s e amplitude ajustada para produzir sensação forte e tolerável. O aparelho foi aplicado por 40 minutos. As puérperas foram avaliadas pela Escala de Categoria Numérica (NRS) e pela Intensidade de Dor Presente (PPI), em duas mamadas, correspondentes a primeira e segunda avaliação. Durante a primeira avaliação as puérperas foram questionadas quanto as características da dor e a presença de outras queixas dolorosas. Na segunda avaliação, o GE recebeu a TENS convencional durante a amamentação e o GC foi apenas acompanhado pelo mesmo período. Após a retirada da TENS do GE e acompanhamento do GC, as mulheres foram questionadas novamente em relação ao nível de dor. Ao final, as puérperas do GE responderam sobre a satisfação do tratamento e desconforto da corrente. Foi realizada análise descritiva para apresentação dos dados e análise comparativa entre os grupos, por meio de teste nãoparamétrico, com nível de significância p<=0,05. A dor de contração uterina apresentou as seguintes características: profunda, localizada em região de baixo ventre e ritmada. O início e diminuição da dor associaram-se com o início e término da sucção, respectivamente. As queixas dolorosas associadas foram dor nas mamas, na região perineal, nos membros superiores e inferiores, na região cervical e na coluna. O PPI indicou que as maiorias das participantes tiveram dor avaliada como moderada e o nível de dor pela NRS foi de 5,53. Na análise intragrupo o GE apresentou redução significativa da dor pela NRS (p<0,0001) após o uso da TENS. O GC também mostrou redução significativa da dor entre a primeira e segunda avaliação (p=0,04). Na análise intergrupo, o GE teve redução significativa da dor pelo PPI (p<0,001) e pela NRS (p<0,01) quando comparado ao GC. As puérperas que utilizaram a TENS relataram estar muito satisfeitas ou satisfeitas com o recurso, utilizariam a técnica em puerpério futuro e não sentiram desconforto causado pela corrente da TENS convencional. A intervenção não causou nenhum tipo de efeitos adversos e colaterais no GE. A TENS convencional foi eficaz no alívio de dor de contração uterina após o parto e durante a amamentação, podendo ser método de escolha para alívio deste tipo de dor.
Título en inglés
Assessment of transcutaneous electrical nerve stimulation to relieve the painful postpartum uterine contractions during breastfeeding: a randomized clinical trial
Palabras clave en inglés
breast feeding
pain
postpartum period
Transcutaneous Electrical Nerve Stimulation.
uterine contraction
Resumen en inglés
During breastfeeding occurs the release of oxytocin for milk ejection, that cause uterine contractions associated with painful process. The transcutaneous electrical nerve stimulation (TENS) is a physical therapy resource, which aims to pain relief. The main objective of this study was to evaluate the effectiveness of TENS to relief of painful uterine contraction during lactation in multiparous after vaginal delivery. The specific objectives were to measure and characterize the uterine contraction pain and identify pain complaints during breastfeeding. This is a randomized, controlled clinical study, formed by 32 multiparous after vaginal delivery, during breastfeeding. The study was conducted with ethical standards and was approved by the Ethics Committee of the Nursing School of Ribeirão Preto - USP. The study was accomplished in a maternity hospital in the state of São Paulo. The participants were placed randomly. The participants were divided in two groups, the experimental group (EG) received the application of conventional TENS and the control group (CG). For EG, the electrodes were placed in the paravertebral region (T10-L1 and S2-S4), programmed to generate frequency of 80Hz, pulse duration of 100?s and intensity adjusted to cause strong feeling and tolerable. The device was applied for 40 minutes. The women were evaluated by Category Numeric Scale (NRS) and Present Pain Intensity (PPI), in two feedings, corresponding to the first and second evaluation. During the first assessment women were asked about pain characteristics and the presence of other pain complaints. In the second evaluation, EG received conventional TENS during breastfeeding and the CG were only accompanied by the same period. After remove the conventional TENS of the EG and monitoring the CG, the women were asked again in relation to the level of pain. In the end, the participants of the EG responded about treatment satisfaction and discomfort of the current. Descriptive analysis was performed for the presentation of data and comparative analysis between the groups, using non-parametric test, with significance level p <= 0.05. The painful uterine contraction had the following characteristics: deep, located in a lower abdomen and rhythmic. The onset and decreased pain associated with the start and end suction, respectively. The pain complaints were breast pain, perineal, in upper extremity, lower extremity, neck and spine. The PPI indicated that the most participants were assessed as moderate pain and pain level was 5.53 for the NRS. In the EG intragroup analysis showed a significant reduction of pain by the NRS (p <0.0001) after use of TENS. The GC also showed significant reduction in pain between the first and second evaluation (p = 0.04). In the intergroup analysis, the EG had significant reduction in pain by the PPI (p <0.001) and the NRS (p <0.01) when compared to CG. The women who used TENS reported being very satisfied or satisfied with the resource, using the technique in future puerperium and felt no discomfort caused by the current of conventional TENS. The intervention did not cause any adverse effects and side effects in EG. The conventional TENS was effective in relieving of uterine contraction pain after delivery and during breastfeeding, may be the method of choice for this type of pain relief.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
LigiadeSousa.pdf (956.16 Kbytes)
Fecha de Publicación
2012-01-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.