Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2013.tde-11092013-160301
Documento
Autor
Nombre completo
Livia Maria de Castro Sousa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2013
Director
Tribunal
Gonçalves, Débora (Presidente)
Carvalho, Antonio José Felix de
Moraes, Marli Leite de
Título en portugués
Estudos sobre a imobilização da polifenoloxidase em filmes de polipirrol/poli-3-metiltiofeno e uso destes filmes em biossensores amperométricos
Palabras clave en portugués
Biossensores
Catecol
Polimetiltiofeno (PMET)
Polipirrol (PPI)
Superoxidação
Tirosinase
Resumen en portugués
Nesta dissertação, foram estudados os métodos de síntese de filmes poliméricos como matrizes hospedeiras da enzima tirosinase vislumbrando o desenvolvimento de biossensores mais seletivos e duradouros na detecção de compostos fenólicos. Os polímeros utilizados e preparados por cronoamperometria em acetonitrila foram: polipirrol (PPI), polimetiltiofeno (PMET) e copolímero PPI-PMET. Os filmes PPI-PMET apresentaram características intermediárias às dos filmes PPI e PMET, conforme se verificaram em espectros na região do infravermelho (FTIR), voltametria cíclica e microscopia de força atômica (AFM), evidenciando, assim, a formação de uma nova matriz polimérica. O processo de superoxidação do filme PPI-PMET foi estudado visando a uma imobilização mais eficiente da enzima, quando se obteve uma condição na qual a superoxidação ocorre somente nas cadeias de PPI. Biossensores amperométricos foram preparados a partir do uso da tirosinase extraída do abacate como fonte enzimática por imobilização física e realizada de maneiras diferentes em filmes não superoxidados e superoxidados. Foi feita a otimização das respostas dos filmes variando-se o pH, potencial de trabalho, concentração da enzima e tempo de imobilização da enzima para a detecção de catecol. Os resultados indicaram que a superoxidação do PPI nos filmes PPI-PMET favoreceu a imobilização da enzima, embora não fosse tão eficiente quando se comparou aos filmes com o PPI não superoxidado. Contudo, os biossensores, em geral, apresentaram grande sensibilidade ao catecol, com um limite de detecção baixo, da ordem de 0,12 µmol/L.
Título en inglés
Studies on the immobilization of polyphenoloxidase polypyrrole/poly-3-methylthiophene films and their use in amperometric biosensors
Palabras clave en inglés
Biosensors
Catechol
Overoxidized
Polymethylthiophene (PMET)
Polypyrrole (PPY)
Tyrosinase
Resumen en inglés
The synthesis methods of polymer films as host matrices of the enzyme tyrosinase were studied in this dissertation. It was expected the development of selective and everlasting biosensors for the detection of phenolic compounds. The used polymers were prepared by chronoamperometry in acetonitrile as followed: polypyrrole (PPI), polymethylthiophene (PMET) and copolymer PPI-PMET. The PPI-PMET films showed intermediate characteristics as the PPI and PMET films, as observed in the infrared spectra (FTIR), cyclic voltammetry and atomic force microscopy (AFM), thus indicating the formation of a new polymeric matrix . The process of overoxidized of PPI-PMET film was studied in order to achieve a more efficient immobilization of the enzyme, whilst it was achieved a condition in which overoxidized occurs only in the PPI chain. Amperometric biosensors were prepared from the use of tyrosinase extracted from avocado as an enzyme source by physical immobilization and performed in different ways in both overoxidized and non-overoxidized films. It was performed the optimization of the responses of the films by varying pH, operacuonial potential, enzyme concentration and time in the enzyme immobilization for the detection of catechol. The results showed that the overoxidized PPI in the films PPI-PMET favored the immobilization of the enzyme, although not as efficient when compared to the films with nom overoxidized PPI. Neverthless, the catechol biosensors showed a high sensitivity with a low detection limit in the order of 0.12 µmol/L.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
DFL.pdf (3.44 Mbytes)
Fecha de Publicación
2013-09-16
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.