Nombre completo
Thais Reggina Kempner
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2016
Director
Tribunal
Oleskovicz, Mário (Presidente)
Costa, Geraldo Roberto Martins da
Kagan, Nelson
Vasconcellos, Arnulfo Barroso de
Vieira Júnior, José Carlos de Melo
Título en portugués
Análise da robustez e da sensibilidade de sistemas de distribuição para a alocação otimizada de medidores frente às variações de tensão de curta duração
Palabras clave en portugués
Alocação ótima de medidores de qualidade da energia
Método das posições de falta
Qualidade da energia elétrica
Sistemas de distribuição
Variações de tensão de curta duração
Resumen en portugués
Como as Variações de Tensão de Curta Duração (VTCDs) estão entre as perturbações mais difíceis de serem monitoradas, uma vez que são ocasionadas por fatores aleatórios e imprevisíveis, a monitoração do Sistema de Distribuição (SD) representa uma providência essencial para a obtenção de informações representativas para a regulamentação de novos indicadores relativos a esses distúrbios. Neste cenário, este trabalho busca garantir a completa observabilidade das VTCDs em SD, quando da incidência de qualquer tipo de curto-circuito, através da alocação ótima de medidores. Para a determinação da magnitude da tensão em cada nó do SD é utilizado o método das posições de falta, denotando assim, a influência e a propagação das VTCDs sobre a rede como um todo. Na sequência, é determinada uma matriz binária resultante que observa os afundamentos de tensão de forma simultânea para todos os tipos de faltas. Posteriormente, é proposta a redução desta matriz para diminuir o esforço computacional em SDs de grande porte. Ainda, é analisada a vulnerabilidade de cada nó do SD para estabelecer a sua posterior ponderação no processo de otimização. Os resultados revelam que a metodologia de alocação apresentada torna o processo de obtenção da solução ótima ágil e direto, pois menos execuções computacionais são necessárias para obter diferentes soluções ótimas e garantir a monitoração dos afundamentos de tensão para todos os tipos de curtos-circuitos. Além disso, pela metodologia, tem-se também a prioridade de instalação dos medidores conforme a maior observabilidade dos afundamentos de tensão, possibilitando a escolha do melhor arranjo de medidores que atenda aos limites orçamentários das distribuidoras de energia.
Título en inglés
Analysis of the robustness and sensitivity of distribution systems for optimal allocation of monitors in face of Short Duration Voltage Variations
Palabras clave en inglés
Distribution systems
Fault position method
Optimal allocation of power quality monitors
Power quality
Short Duration Voltage Variation
Resumen en inglés
Short Duration Voltage Variations (SDVVs) are among the most difficult disturbances to be monitored, since they are caused by random and unpredictable factors. Hence, the Distribution System (DS) monitoring is an essential step for obtaining representative information for the regulation of new power quality indices for these disturbances. In this scenario, this work aims to ensure the entire observability of SDVVs, considering any short circuit occurrence in the DS, based on algorithm to achieve the monitors' optimal allocation. In order to determine the voltage magnitude at each node, the fault positions method is used, showing the influence and propagation of SDVVs on the DS. Subsequently, a resulting binary matrix is determined. This matrix observes the voltage sags, simultaneously, for all fault types. Then, the downsizing of this matrix is proposed in order to reduce the computational effort in large DSs. Furthermore, the vulnerability of each DS node is analyzed to establish the relative weighting in the optimization process. The results show a faster and more direct allocation methodology to obtain the optimal solution, because fewer computational executions are needed for different optimal solutions and to ensure the voltage sags monitoring for all short circuits types. Moreover, the power quality monitor installation priority is performed according to the higher observability of the voltage sags, making it possible to choose the best arrangement of monitors that meets the budget constraints of the power utilities.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Thais.pdf (7.43 Mbytes)
Fecha de Publicación
2016-08-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.