Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2021.tde-27082021-153535
Documento
Autor
Nombre completo
Geovane Michael Lentz
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2021
Director
Tribunal
Alberto, Luís Fernando Costa (Presidente)
Dotta, Daniel
Taranto, Glauco Nery
Título en portugués
Um novo índice inspirado em Equivalente de Thévenin para monitorar a estabilidade de tensão em sistemas elétricos de potência
Palabras clave en portugués
Bifurcações sela-nó
Colapso de tensão
Estabilidade de tensão
Máxima transferência de potência
Teorema de Thévenin
Unidades de medições fasoriais
Resumen en portugués
Neste trabalho, estudam-se métodos para monitorar Margens de Estabilidade de Tensão (MET) de Sistemas Elétricos de Potência (SEP) por meio dos Sistemas de Medição Fasorial Sincronizada (SMFS). Na literatura, muitos autores utilizaram os SMFS para avaliar a estabilidade de tensão de maneira estática em tempo real. Dentre as ferramentas existentes para avaliar a MET utilizando SMFS, as que se destacam são: o equivalente de Thévenin, as redes neurais artificiais, diferentes índices de estabilidade de tensão e o expoente de Lyapunov. Porém, esses métodos podem apresentar problemas devido a aproximações e/ou suposições não exatas na modelagem do problema. Esse trabalho tem como objetivo avaliar estes problemas e propor um novo índice para avaliar a estabilidade de tensão de maneira estática, baseadas em informações obtidas dos SMFS. O índice proposto é inspirado no teorema de Thévenin. Métodos baseados no teorema de Thévenin procuram estimar o Ponto de Máximo Carregamento (PMC) do sistema determinando o ponto de Máxima Transferência de Potência (MTP) em alguma barra do sistema. Para isso, utilizam as informações das medidas de tensão e corrente obtidas através do SMFS em uma barra do sistema para determinar um circuito equivalente, constituído de uma fonte de tensão em série com uma impedância, que representa todo o sistema visto a partir daquela barra. Diferentemente da abordagem tradicional, desenvolveu-se uma condição de MTP que leva em consideração a variação do circuito equivalente com a variação da carga. Para esta condição, o ponto de MTP não ocorre quando o módulo da impedância da carga é igual ao módulo da impedância do circuito equivalente. Demonstra-se que o método proposto para detectar o ponto de MTP explorando a condição de MTP desenvolvida nesta dissertação a partir de medidas de PMUs é mais exato, evitando alguns erros de aproximação na modelagem do problema.
Título en inglés
A new index inspired by Thévenin equivalent to monitor voltage stability in electrical power systems
Palabras clave en inglés
Maximum power transfer
Phasor measurement units
Saddle-node bifurcations
Thévenin\'s Theorem
Voltage collapse
Voltage stability
Resumen en inglés
In this work, methods to monitor Voltage Stability Margins (VSM) of Electrical Power Systems (EPS) using Synchronized Phasor Measurement Systems (SPMS) are studied. In the literature, many authors have used SPMS to statically assess voltage stability in real time. Among the existing tools to assess VSM using SPMS, the ones that stand out are: the Thevenin equivalent, the artificial neural networks, different voltage stability indices and the Lyapunov exponent. However, these methods can present problems due to inaccurate approximations and/or assumptions in the modeling of the problem. This work aims to evaluate these problems and propose a new index to statically assess the voltage stability, based on information obtained from the SPMS. The proposed index is inspired by Thevenin's theorem. Methods based on Thevenin's theorem seek to estimate the Maximum Load Point (MLP) of the system by determining the Maximum Power Transfer (MPT) point at some bus in the system. For this, they use the information from the voltage and current measurements obtained from the SPMS on a system bus to determine an equivalent circuit, consisting of a voltage source in series with an impedance, which represents the entire system seen from that bus. Unlike the traditional approach, a MPT condition has developed that takes into account the variation of the equivalent circuit with the variation of the load. For this condition, the MPT point does not occur when the module of the load impedance is equal to the module of the impedance of the equivalent circuit. It is demonstrated that the proposed method to detect the MPT point, exploring the MTP condition developed in this dissertation from PMUs measurements, is more accurate, avoiding some approximation errors in the modeling of the problem.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2021-08-31
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.