• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2013.tde-26082013-133347
Document
Auteur
Nom complet
Klaus Vieira do Nascimento
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2013
Directeur
Jury
Vieira Júnior, José Carlos de Melo (Président)
Flauzino, Rogério Andrade
Serni, Paulo José Amaral
Titre en portugais
Metodologia de análise de variações de tensão causadas pela proteção anti-ilhamento de geradores síncronos distribuídos
Mots-clés en portugais
Distribuição de energia elétrica
Geração distribuída
Ilhamento
Qualidade de energia
Variações de tensão
Resumé en portugais
Nos últimos anos, fatores como a reestruturação do setor de energia elétrica, a necessidade de aproveitamento de diferentes fontes primárias de energia, dificuldades na construção de grandes unidades geradoras e linhas de transmissão causadas por normas de proteção ambiental têm provocado o aumento considerável do interesse por geração distribuída. O conceito de geração distribuída tornou-se muito interessante, entretanto, sua aplicação pode provocar problemas de qualidade de energia elétrica, caso sua influência não seja devidamente estudada. Neste contexto, este documento caracteriza as variações de tensão causadas pela atuação da proteção anti-ilhamento de geradores síncronos distribuídos. Este problema pode ser considerado uma nova abordagem sobre os impactos dos geradores distribuídos na qualidade da energia elétrica, visto que as causas das variações de tensão são tipicamente relacionadas às tomadas ou alívios de grandes blocos carga, partidas de motores de indução, curtos-circuitos, desligamentos de linhas etc. Para estudar o problema, inicialmente foi feito um estudo sobre normatização técnica da área com um apanhado dos guias de diversas concessionárias. Posteriormente, simulações computacionais utilizando o programa SimPowerSystems e um sistema teste foram utilizados para que análises estáticas e dinâmicas do problema fossem feitas no intuito de investigar a natureza das variações de tensão e os fatores que influenciam suas magnitudes e durações. Índices para avaliar as variações de tensão foram criados, e um método para obtenção dos mesmos foi proposto. Tal método utiliza apenas ferramentas de análise estática (fluxo de carga) para a obtenção dos índices, evitando o uso de ferramentas dinâmicas (domínio do tempo) reduzindo o custo computacional e financeiro para análise do problema. Em seguida, o mesmo foi aplicado a um sistema que simula uma rede de distribuição real propondo-se a inserção de bancos de capacitores como medida mitigatória para o problema estudado neste trabalho.
Titre en anglais
Methodology for analysis of voltage variations caused by anti-island protection of distributed synchronous generators
Mots-clés en anglais
Distributed generation
Islanding
Power distribution
Power quality
Voltage variation
Resumé en anglais
In recent years, factors such as the restructuring of the electricity sector, the necessity to use different primary energy sources as a way to diversify sources of energy, barriers in the construction of large generating units and transmission lines caused by environmental protection standards, as well as technological advances in the generation of electricity, have caused a considerable increase in the interest for distributed generation. The concept of distributed generation has become very interesting; however, its application can result in poor power quality, if its influence is not well studied. In this context, this document characterizes voltage variations caused by the action of anti-islanding protection of distributed synchronous generators. This problem can be considered a new approach on the impact of distributed generators in power quality, since the cause of voltage variations are typically related load switching, induction motors start-up, short circuits, lines disconnection, etc. To investigate the problem, initially a study was carried out on technical standardization in the area with an overview of various utilities guides. Later, computer simulations using the SimPowerSystems software and a test system were employed for static and dynamic analysis of the problem, aiming at investigating the nature of voltage variations and the main factors that influence their magnitudes and durations. Indices to assess the voltage variations were created, and a method for obtaining them was proposed. This method uses only static approach tools (power flow calculations) to obtain the indices, avoiding the use of dynamic tools (time-domain simulations) and reducing computational and financial costs to analyses the problem. The proposed method was applied to a larger system and the insertion of capacitors bank was proposed as mitigating solution for the problem studied in this work.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Klaus.pdf (2.38 Mbytes)
Date de Publication
2013-08-30
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.