• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.18.2017.tde-21062017-140600
Document
Author
Full name
Rafael Cruz Borges
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2017
Supervisor
Committee
Ramos, Rodrigo Andrade (President)
Kopcak, Igor
Oliveira, Ricardo Vasques de
Pavani, Ahda Pionkoski Grilo
Vieira Júnior, José Carlos de Melo
Title in Portuguese
Análise da influência de motores de indução sobre o comportamento dinâmico de um DFIG conectado a um sistema de distribuição
Keywords in Portuguese
DFIG
FIDVR
Geração distribuída
Oscilações eletromecânicas
Abstract in Portuguese
Com o advento da geração distribuída, a operação do sistema de distribuição tem se modificado. Características dinâmicas que antes eram observadas somente no sistema de transmissão agora também podem estar presentes em sistemas de distribuição, como por exemplo, problemas relacionados às oscilações eletromecânicas. Devido à perspectiva de crescimento de conexões de geradores eólicos, fica evidente a possibilidade do aumento na produção de energia elétrica através de geradores assíncronos distribuídos. No sistema de distribuição estão presentes vários tipos de cargas, sendo uma das mais representativas, as cargas do tipo motor de indução. Este tipo de carga, na ocorrência de curto-circuitos no sistema pode provocar atraso na recuperação da tensão do sistema, conhecido como problema Fault Induced Delayed Voltage Recovery (FIDVR). Depois que a falta é eliminada, a tensão pode permanecer em níveis significativamente reduzidos durante vários segundos. Esse atraso de tempo é geralmente causado pela alta concentração de motores de indução. Portanto, torna-se necessária a realização de estudos para analisar os impactos que esse tipo de fonte de energia pode trazer para o sistema elétrico bem como o impacto das cargas sobre o gerador eólico. Assim, este trabalho faz uma análise da influência de cargas do tipo motor de indução sobre o comportamento dinâmico de um DFIG conectado a um sistema de distribuição. Um gerador síncrono convencional também foi utilizado para fazer uma comparação com o DFIG. Como os dois geradores estão atuando com regulação de tensão, seria intuitivo pensar que as respostas dos dois na presença de cargas do tipo motor de indução, fossem semelhantes. No entanto, este trabalho mostra que diante do mesmo cenário, as máquinas têm comportamentos diversos e a reação é diferente dependendo do tipo de carga conectada ao sistema. Foi verificado que, quando existe o problema FIDVR devido à presença de cargas do tipo motor de indução, as oscilações na velocidade do DFIG são amplificadas. Já para o gerador síncrono, a carga do tipo motor de indução possui pouca influência nas oscilações eletromecânicas.
Title in English
Analysis of the influence of induction motors under the dynamic behavior of a DFIG connected to a distribution system
Keywords in English
DFIG
Distributed generation
Electromechanical oscillations
FIDVR
Abstract in English
With the advent of distributed generation, the operation of the distribution system has been modified. Dynamic characteristics that were previously observed only in the transmission system can now also be present in distribution systems, such as problems related to electromechanical oscillations. Due to growth prospects of wind generator connections, it is evident the possibility of increasing the production of electricity through asynchronous distributed generators. In the distribution system several types of loads are present, being one of the most representative the loads of type induction motor. This type of load, the occurrence of short-circuits in the system can cause delay in the recovery of the system voltage, known as Fault Induced Delayed Voltage Recovery (FIDVR) problem. After the fault is eliminated, the voltage can remain at significantly reduced levels for several seconds. This time delay is usually caused by the high concentration of induction motors. So, it is necessary to perform studies to analyze the impacts that this type of energy source can bring to the electrical system as well as the impact of the loads on the wind generator. Thus, this thesis makes an analysis of the influence of induction motor loads on the dynamic behavior of a DFIG connected to a distribution system. A conventional synchronous generator was also used to make a comparison with the DFIG. As the two generators are working with voltage regulation, it would be intuitive to think that the responses of the two in the presence of induction motor loads would be similar. However, this thesis shows that in the same scenario, the machines have different behaviors and the reaction is different according to the type of load connected to the system. It was verified that when there is the FIDVR problem due to the presence of the induction motor, the oscillations in the speed of the DFIG are amplified. For the synchronous generator, the induction motor has little influence on the electromechanical oscillations.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Rafael.pdf (5.13 Mbytes)
Publishing Date
2017-06-22
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.