Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2009.tde-16112009-164527
Documento
Autor
Nombre completo
Antonio Carlos Leal de Castro Junior
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2009
Director
Tribunal
Bretas, Newton Geraldo (Presidente)
Alberto, Luís Fernando Costa
Silva, Luiz Carlos Pereira da
Título en portugués
Estudo de controle preventivo para análise do colapso de tensão
Palabras clave en portugués
Colapso de tensão
Estabilidade de tensão
Fluxo de carga continuado
Sistemas elétricos de potência
Resumen en portugués
Até meados da década de setenta a atenção dos técnicos do setor elétrico estava voltada aos problemas advindos da chamada instabilidade de ângulo, onde perturbações mais severas, tais como curtos-circuitos, levam os sistemas a perderem estabilidade. À medida que os sistemas foram ficando mais sobrecarregados, algumas não linearidades tornaram-se mais evidentes e problemas que até então não eram observados passaram a ocorrer. Um desses problemas que passou a despertar maior atenção dos engenheiros de potência foi justamente o problema de colapso de tensão. Tal fenômeno está relacionado à incapacidade do sistema elétrico de prover o balanço entre a potência gerada e a requisitada pelas cargas, devido, principalmente, à limitada capacidade de transmissão, ou ainda, devido a um suporte de potência reativa local inadequada. Neste trabalho pretende-se avaliar o grau de impacto que uma contingência ou uma ação de controle teria sobre um sistema de potência. Para avaliar este grau de impacto pretende-se utilizar os conceitos de coerência de cargas, a partir da matriz de impedância nodal, determinando-se quais barras seriam mais influenciadas por uma certa perturbação no sistema. Quando este número de barras é elevado, indica que a contingência deveria ser classificada como mais grave do que uma contingência com margem baixa, porém de impacto local e de fácil solução. Durante o funcionamento do sistema podem ocorrer eventos que afetam as características de tensão e freqüência, causando inclusive a interrupção do fornecimento de energia. Portanto, o engenheiro de operação deve dispor de ferramentas que controlem e que permitam prever esta situação de risco e tomar medidas para evitá-las. Assim, é de extrema importância, a análise de estabilidade do sistema, a fim de em um futuro próximo, prevenir distúrbios no seu funcionamento normal.
Título en inglés
Study of preventive control for the analysis of voltage collapse
Palabras clave en inglés
Electrical power systems
Load flow continued
Preventive control
Voltage collapse
Voltage stability
Resumen en inglés
Until the middle of the seventies the attention of the technicians of the electricity sector was focused on the problems arising from instability of the callangle, where the most severe, such as short circuits, take the systems to lose stability. As the systems were getting overloaded, some nonlinearities have become more evident and problems that were not seen until then began to occur. One such problem that has awaken the attention of power engineers was precisely the problem of voltage collapse. This phenomenon is related to the inability of the electric system to provide the balance between power generated and required by the loads, mainly due to the limited transmission capacity, or because a local reactive power support inadequate. This work aims to assess the degree of impact that a contingency or an action of control would have on a system of power. To assess the degree of impact is intended to use the concepts of consistency of loads from the nodal impedance matrix, it was determined that bars would be more influenced by a disturbance in the system. When this number of bars is high, indicates that the contingency should be classified as more serious than a contingency margin with low, but the local impact and easy solution. During operation of system events may occur that affect the characteristics of voltage and frequency, causing even the interruption of power supply. Therefore, the operating engineer should have the tools to monitor and to predict that this situation of risk and take steps to avoid them. It is therefore of extreme importance, the analysis of system stability, so that in the near future, to prevent disturbances in their normal operation.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Antonio.pdf (1.02 Mbytes)
Fecha de Publicación
2009-11-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.