• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2009.tde-12112009-090143
Documento
Autor
Nombre completo
Débora Maria Barbosa Salvador de Souza
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2009
Director
Tribunal
Silva, Ivan Nunes da (Presidente)
Flauzino, Rogério Andrade
Mantovani, José Roberto Sanches
Título en portugués
Abordagem baseada em lógica fuzzy para alocação de indicadores de faltas em sistemas de distribuição de energia elétrica
Palabras clave en portugués
Indicador de faltas
Restabelecimento de energia
Sistemas de distribuição
Sistemas fuzzy
Resumen en portugués
Este trabalho apresenta uma metodologia para alocação eficiente de dispositivos indicadores de faltas em sistemas de distribuição de energia elétrica. São avaliadas como as principais variáveis que influenciam na quantificação da potencialidade para instalação de dispositivos indicadores de faltas se comportam ao longo do tronco principal dos alimentadores de distribuição de energia elétrica. Como metodologia, empregou-se sistemas de inferência fuzzy para quantificar a referida potencialidade a partir das variáveis avaliadas. Resultados com dados reais destacam também a eficiência da metodologia proposta para quantificar e avaliar a rede de dispositivos indicadores já existentes em alimentadores.
Título en inglés
Approach based on fuzzy logic for fault indicator allocation in power distribution systems
Palabras clave en inglés
Fault indicators
Fuzzy systems
Power distribution system
System reestablishment
Resumen en inglés
This work presents a methodology for efficient allocation of fault indicator devices in electric power distribution systems. The behavior of the main variables that influence in the quantification of the potentiality for installation of fault indicator devices were analyzed taking into account the feeder length. In methodology terms, fuzzy inference systems were used to quantify this potentiality from the analyzed variables. Results with real data have also highlighted the efficiency of the proposed methodology to quantify and to evaluate the fault indicator device network already existent in power distribution feeders.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Debora.pdf (2.90 Mbytes)
Fecha de Publicación
2009-11-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.