Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2013.tde-27032013-093519
Document
Auteur
Nom complet
Renan Fernandes Bastos
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2013
Directeur
Jury
Machado, Ricardo Quadros (Président)
Michels, Leandro
Monteiro, José Roberto Boffino de Almeida
Titre en portugais
Sistema de gerenciamento para carga e descarga de baterias (chumbo-ácido) e para busca do ponto de máxima potência gerada em painéis fotovoltaicos empregados em sistemas de geração distribuída
Mots-clés en portugais
Bateria chumbo-ácido
Controlador fuzzy
Conversor CC-CC bidirecional
Eletrônica de potência
Fontes alternativas
Geração distribuída
Painéis fotovoltaicos
Resumé en portugais
O presente trabalho visa o desenvolvimento de um sistema de carga e descarga de baterias de chumbo-ácido para sistemas de geração distribuída acoplada a um conjunto de painéis fotovoltaicos e conectada à rede elétrica. O conjunto de painéis opera de forma a maximizar a energia gerada através de um algoritmo MPPT (Maximum Power Point Tracking) e a rede elétrica opera como rota para o excedente produzido pelos painéis. Para que a bateria possa ser carregada e descarregada com eficiência evitando sobrecargas e descarregamentos profundos, uma metodologia de estimação do estado de carga da bateria é implementada visando um controle mais eficiente (maximizando a vida útil da bateria) e um melhor aproveitamento da energia armazenada. Para o gerenciamento da carga e descarga do banco de baterias é utilizada uma topologia bidirecional (Boost-Buck) com controlador fuzzy P+I para estabilização de corrente ou tensão. Em relação à técnica de controle para o sistema PV, um controlador PI clássico é utilizado para regular a tensão terminal e ponto de máxima potência que é definido por um algoritmo de perturbação e observação (P&O). Para validar os controladores e os modelos teóricos desenvolvidos é construído um protótipo do sistema. São analisados, também, o comportamento do sistema de carga das baterias e painel fotovoltaico sob condições extremas como queda abrupta de irradiação solar, desconexão inesperada dos painéis e mudanças no ponto ótimo de funcionamento dos mesmos.
Titre en anglais
Management system for charging and discharging of batteries (lead acid) and search for the maximum power point generated on photovoltaic panels employed in distributed generation systems
Mots-clés en anglais
Alternative sources
Bidirectional DC-DC converter
Distributed generation
Fuzzy controller
Lead-acid battery
Power electronics
PV arrays
Resumé en anglais
The present work aims to develop a system of charging and discharging lead-acid batteries for distributed generation connected to a set of photovoltaic panels, and used in grid connected applications. The set of panels operates to maximize the energy produced by means of an MPPT (Maximum Power Point Tracking) algorithm and the power grid absorbs the extra power produced by the panels. For charging and discharging the battery pack and to prevent overload and deep discharge, a methodology for estimating the state of charge is implemented in order to obtain an efficient control technique (maximizing battery life), and more efficient use of the stored energy. To manage the charging and discharging of the battery bank a bidirectional topology (Boost-Buck) with fuzzy P+I controller for stabilization of current or voltage is used. To regards the PV control technique, a classical PI controller is employed to regulate the PV terminal voltage, and the maximum power point is determined by a perturb and observe (P&O) algorithm. To validate the controllers and the theoretical models developed is built a prototype system, and analyzed the behavior of the batteries charger and photovoltaic panel under extreme environmental conditions such as abrupt decrease of solar irradiation, unexpected panels disconnection and changes of the maximum power point of the panels.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Bastos.pdf (6.51 Mbytes)
Date de Publication
2013-03-28
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.