Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2010.tde-10082010-135546
Document
Author
Full name
Débora Regina Malvesi Stemberg
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2010
Supervisor
Committee
Schiabel, Homero (President)
Furquim, Tânia Aparecida Correia
Martinelli, Simone Elias
Title in Portuguese
Desenvolvimento de simulador mamográfico para avaliação de esquemas CAD
Keywords in Portuguese
Esquemas CAD
Mamografia
Processamento de imagens mamográficas
Simulador radiográfico
Abstract in Portuguese
Visando a um melhor desempenho na avaliação de imagens mamográficas, diversos trabalhos utilizando técnicas de processamento de imagem vêm sendo desenvolvidos como parte de esquemas computacionais que auxiliam o diagnóstico, denominados de esquemas CAD. Entretanto, um dos maiores desafios no desenvolvimento destes sistemas está relacionado com a avaliação de seu desempenho, que pode apresentar inconsistências, como impossibilidade de comparação dos resultados devido à dificuldade de se obter bancos de imagens amplos, comuns e confiáveis, que apresentem características de aquisição variadas atendendo aos requisitos específicos da técnica. Este trabalho tem por objetivo auxiliar nesse campo, apresentando um protótipo de simulador radiográfico de mama que possibilite gerar imagens que se assemelhem às de uma mamografia real através ainda de uma distribuição aleatória das estruturas de interesse simuladas. Isso permite a aquisição de um grande conjunto de imagens, por diferentes formas e condições, tornando possível testar e avaliar com maior precisão o desempenho de esquemas CAD destinados à mamografia. Tem a virtude de dispensar a validação dos resultados apontados pelo esquema com base no laudo do especialista, visto que é possível saber previamente quais são e quantas são as estruturas presentes em cada imagem, bem como a localização exata de cada uma delas. Portanto, torna-se possível assegurar com confiança a eficácia e viabilidade do esquema CAD testado, tanto em relação ao resultado apresentado pelo sistema quanto em relação à minimização de erros sistemáticos, dada a aleatoriedade da distribuição das estruturas-alvo da avaliação, como ocorre no exame real.
Title in English
Development of a breast Phantom for CAD schemes evaluation
Keywords in English
CAD schemes
Mammographic images processing
Mammography
Phantom
Abstract in English
In order to obtain a better performance in the evaluation of mammographic images, several studies using image processing techniques have been developed as part of computer aided diagnosis, known as CAD systems. However, one of the main challenges in the development of such schemes is the performance evaluation, which may present problems, as such as difficulty in comparing results due to the inability to obtain large and common databases with wide-ranging characteristics of image acquisition. This work has the purpose of helping in this field, by presenting a breast phantom to allow obtaining images closer to those from actual mammography due to a random distribution of simulated interest structures. This provides to get a large images set, obtained from different conditions, and it allows to evaluate more accurately the performance of mammography CAD schemes. The use of this phantom has also the advantage of validating the scheme results without using the radiological report, since it provides the exact knowledge of the number and characteristics of the structures present in the image, as well as their positioning. Therefore, the efficacy and feasibility of a CAD scheme under test can be assured, regarding the results and also by the minimization of systematic errors due to the random distribution of the structures of clinical interest, similarly to the actual exam.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Debora.pdf (3.33 Mbytes)
Publishing Date
2010-09-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.