  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2007.tde-07042008-130554
Document
Author
Full name
Luciano Alcindo Schühli
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2007
Supervisor
Committee
Oliveira, João Fernando Gomes de (President)
Hassui, Amauri
Valente, Carlos Magno de Oliveira
Title in Portuguese
Monitoramento de operações de retificação usando fusão de sensores
Keywords in Portuguese
Emissão acústica
Fusão de sensores
Monitoramento de processos de retificação
Potência
Processos de fabricação
Retificação
Abstract in Portuguese
O presente trabalho trata da análise experimental de um sistema de monitoramento baseado na técnica de fusão de sensores, aplicado em uma retificadora cilíndrica externa. A fusão é realizada entre os sinais de potência e emissão acústica para obtenção do parâmetro FAP (Fast Abrasive Power) através do método desenvolvido por Valente (2003). Através da simulação de problemas encontrados nos processos de retificação (falha de sobremetal, colisão, desbalanceamento e vibração), foram captados os sinais de potência e emissão acústica e a partir destes gerado o parâmetro FAP, comparando seu desempenho, na detecção dos problemas, com os outros dois sinais. Para a análise foram construídos os gráficos das variações dos sinais em relação ao tempo de execução do processo e os mapas do FAP e acústico. O sistema de monitoramento avaliado tem como característica baixa complexidade de instalação e execução. Os dados experimentais revelam que o FAP apresenta uma velocidade de resposta maior que a potência e levemente amortecida em relação à emissão acústica. O nível do seu sinal é igual ao da potência mantendo-se homogêneo durante o processo, ao contrário da emissão acústica que pode ser influenciada por diversos outros parâmetros, tais como geometria da peça, distância do sensor, montagem do sensor, entre outros, que independem da interação ferramenta-peça. O resultado é uma resposta dinâmica e confiável, associada à energia do sistema. Estas características são interessantes para o monitoramento de processos de retificação (excluindo a dressagem) sendo superiores àquelas apresentadas isoladamente pelos sinais de potência e emissão acústica.
Title in English
Monitoring of operations the rectification using sensors of fusion
Keywords in English
Grinding acoustic emission
Grinding monitoring
Manufacturing process
Power
Sensor fusion
Abstract in English
The present study deals with an experimental analysis of a monitoring system based on a sensor fusion strategy applied to a cylindrical grinding machine. It comprises a fusion of the power and acoustic emission signals and has as main goal to obtain the FAP (Fast Abrasive Power) using the method developed by Valente (2003). Initially, the power and acoustic emission signals were captured under operational dysfunction conditions during the grinding process (stock imperfection, collision, unbalancing e vibration). Then, based on these signals, the FAP parameter was generated and its capability in characterizing operational dysfunctions evaluated against the performance of an individual analysis of the power and acoustic emission signals. For this analysis, FAP and acoustic maps plus plots showing the FAP signals vs. working time were implemented. The experimental data revealed that the FAP presents a faster response than the power signal and a slightly dumped response when compared against the acoustic signal. The signal level of the FAP is similar to the power signal and is homogenous during the machining process. On contrary to the FAP, the acoustic emission signal may be affected by parameters that are not related to the tool-workpiece interactions, workpiece geometry and sensor positioning. The dynamic response of FAP is reliable and linked to the energy of the system. Finally, it should be highlightened that the monitoring system based on the FAP parameter presents low complexity in both implementation and execution. Such characteristics are superior to those observed when using either the power or acoustic emission signals and highly valuable in a system designed to monitor grinding processes.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2008-04-09
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.